MIL-STD-461 is the US Department of Defense standard for controlling electromagnetic interference (EMI) in military equipment. It splits EMC into 19 separately numbered test methods: CE (conducted emissions), CS (conducted susceptibility), RE (radiated emissions) and RS (radiated susceptibility). The current revision is MIL-STD-461H, released on 17 April 2026, which supersedes MIL-STD-461G (December 2015). Which methods apply, and at what limits, depends on the platform the equipment goes into: aircraft, surface ship, submarine, ground vehicle or ground facility.
This guide decodes the method names, lists every test with its frequency range, explains what changed in 461H, and shows the equipment you need to run the tests in-house, including MIL-STD shielded chambers, RF power amplifiers and EMC antennas.

Updated November 2026.
How to Read a MIL-STD-461 Test Name
Every method is two letters and three digits. The letters tell you what is being tested; the number identifies the specific method.
| Prefix | Meaning | What it checks |
|---|---|---|
| CE | Conducted Emissions | Noise the equipment puts back onto its power leads or antenna terminals |
| CS | Conducted Susceptibility | Whether it keeps working when interference is injected onto its cables and power leads |
| RE | Radiated Emissions | Electric and magnetic fields it radiates into the space around it |
| RS | Radiated Susceptibility | Whether it keeps working when exposed to external fields |
So RE102 is a radiated emissions test (electric field) and RS103 is a radiated susceptibility test (electric field). The 101 methods are generally the low-frequency or magnetic versions.
All 19 MIL-STD-461 Test Methods
| Method | What it covers | Frequency range |
|---|---|---|
| CE101 | Conducted emissions, audio-frequency currents, power leads | 30 Hz – 10 kHz (to 20 kHz for surface ships and submarines in 461H) |
| CE102 | Conducted emissions, RF potentials, power leads | 10 kHz – 10 MHz |
| CE106 | Conducted emissions, antenna terminal | 10 kHz – 40 GHz |
| CS101 | Conducted susceptibility, power leads | 30 Hz – 150 kHz |
| CS103 | Antenna port, intermodulation | Set by receiver band |
| CS104 | Antenna port, rejection of undesired signals | Set by receiver band |
| CS105 | Antenna port, cross-modulation | Set by receiver band |
| CS109 | Structure current | 60 Hz – 100 kHz |
| CS114 | Bulk cable injection (BCI) | 10 kHz – 200 MHz |
| CS115 | Bulk cable injection, impulse excitation | Pulse test |
| CS116 | Damped sinusoidal transients, cables and power leads | 10 kHz – 100 MHz |
| CS117 | Lightning-induced transients | Pulse test |
| CS118 | Personnel-borne electrostatic discharge | ESD test |
| RE101 | Radiated emissions, magnetic field | 30 Hz – 100 kHz |
| RE102 | Radiated emissions, electric field | 10 kHz – 18 GHz |
| RE103 | Antenna spurious and harmonic outputs | 10 kHz – 40 GHz |
| RS101 | Radiated susceptibility, magnetic field | 30 Hz – 100 kHz |
| RS103 | Radiated susceptibility, electric field | 2 MHz – 40 GHz (upper limit depends on platform) |
| RS105 | Transient electromagnetic field | Pulse test |
Not every method applies to every product. The standard's applicability table marks each method as applicable, limited or procuring-activity specified for each platform, so an aircraft box, a ship system and a ground-vehicle unit can have quite different test lists.
What Changed in MIL-STD-461H (2026)
MIL-STD-461H was released on 17 April 2026 and supersedes MIL-STD-461G (December 2015). It adds no new test methods and needs no new test equipment, but several changes affect how a lab scans, sets up and reports.
| Area | Change in 461H | What it means for your lab |
|---|---|---|
| Stepped receivers (4.3.10.3.3) | Step size reduced from half to a quarter of the measurement bandwidth or smaller | Roughly double the minimum scan time per antenna position and polarisation |
| Analog receivers (Table II) | Bandwidth and measurement-time column for analog-tuned receivers removed | Check sweep settings if you still use analog receivers |
| Measurement tolerances (4.3) | Tolerances in 4.3.1 shall not be used to assess compliance against the limits | No arguing a marginal result into a pass |
| Overload and ambient (4.3.7.3, 4.3.4) | Overload precautions are now required, with each measurement shown free of overload; the ambient level must be recorded | Extra checks and records in every emissions test |
| Primary power leads (3.1.8, 3.1.12) | New definitions; CE101, CE102 and CS101 apply only to leads that connect directly to the platform power bus | Fewer leads may need these tests; document why |
| Cable layout (4.3.8.6) | Primary power leads routed as individual conductors, input lead first, 10 cm from the front edge | Revise bench setups and drawings |
| CE101 | Limit range extended to 20 kHz for surface ships and submarines; non-Navy aircraft stay at 10 kHz | Wider scan for Navy programs |
| CS114 | Data presentation requires plots of forward power and measured current against frequency; 77 dBµA limit now also applies to Army ships | Automated, logged calibration and test runs |
| RE101 and RE102 | Each EUT surface scanned and significant emission locations documented (RE101); horn elevation kept parallel to the floor (RE102) | More detailed scans and records |
| Test reports | Photographs with dimensional references of the setup, grounding, probe and antenna positions | Plan photography into every test |
Existing contracts keep the revision they were written against, so many Australian and New Zealand defence suppliers will be testing to 461G, 461F or even 461E for years yet. Always check which revision and which tailoring your contract calls up. This summary is based on published reviews of the new revision; check the standard itself before changing procedures.
How the Test Setup Differs from Commercial EMC
| MIL-STD-461 | Commercial (CISPR / IEC) | |
|---|---|---|
| Test site | Shielded enclosure with absorber-lined walls | Open area test site or semi-anechoic chamber |
| EUT position | On a bonded ground-plane bench, 10 cm from the front edge | Table-top or floor-standing on a turntable |
| Antenna distance | 1 m from the bench edge | 3 m or 10 m |
| Power line network | 50 µH LISN on each power lead | 50 µH/50 Ω LISN to CISPR 16 |
| Emissions detector | Peak detector | Quasi-peak and average |
| Cable layout | Cables 5 cm above the ground plane | Specified by product standard |
Because the geometry is different, results from a commercial lab can't simply be reused for MIL-STD-461, and the reverse. Our EMC standards cross-reference compares the main commercial, automotive and aerospace standards side by side.
RE102 and RS103: The Tests That Size Your Lab
RE102 measures radiated electric fields from 10 kHz to 18 GHz using a rod, biconical, double-ridged horn and other antennas at 1 m. It is widely cited as one of the most commonly failed MIL-STD-461 tests, usually because of cable radiation and switching power supply noise.
RS103 exposes the equipment to a calibrated electric field, typically between 20 V/m and 200 V/m depending on the platform and location, from 2 MHz up to 18 GHz or 40 GHz. Generating 200 V/m across a wide band at 1 m is what drives the size and cost of your RF power amplifiers and high-gain horn antennas. RS103 can also be run in a reverberation chamber above its lowest usable frequency, which reaches high fields with much less amplifier power. See reverberation chambers for DO-160 and MIL-STD-461.
Equipment Needed for MIL-STD-461 Testing
| Methods | Core equipment | Finch range |
|---|---|---|
| All radiated tests | Shielded enclosure with absorber, bonded ground-plane bench | RF Technology MIL-STD chamber |
| CE101, CE102 | 50 µH LISNs, EMI receiver or spectrum analyser, current probe | Conducted emissions equipment |
| RE102 | EMI receiver, rod, biconical and horn antennas, preamplifiers | EMC antennas, EMI preamplifiers |
| RS103 | Signal generator, broadband power amplifiers, transmit antennas, field probe | RF EMC power amplifiers, RFlight broadband amplifiers |
| RS103 (alternative) | Mode-stirred reverberation chamber | RF Technology reverberation chamber |
| CS114, CS116 | Injection and monitor probes, power amplifier, damped sine generator | Conducted immunity equipment |
Equipment that runs from aircraft power also needs a suitable supply during the test; see 400 Hz ground power and MIL-STD-704.
Tailoring
MIL-STD-461's appendix expects the procuring activity to tailor the default requirements for each program: adding or removing methods, changing limits, or adjusting frequency ranges. Before you buy equipment or book chamber time, get the tailored test plan, because it decides the frequency range of your amplifiers, the field strength you need and which transient generators are required.
MIL-STD-461 Testing in Australia and New Zealand
Finch supplies and supports MIL-STD-461 test facilities in Australia and New Zealand, from complete shielded MIL-STD chambers to the amplifiers, antennas and conducted test equipment that go in them. We can size a system from your tailored test plan and the platforms you supply. Talk to our Melbourne team.
Frequently Asked Questions
What is the latest version of MIL-STD-461? MIL-STD-461H, released on 17 April 2026. It supersedes MIL-STD-461G (December 2015) and applies to programs started after its release. Existing contracts keep the revision they call up.
What do CE, CS, RE and RS mean in MIL-STD-461? CE is conducted emissions, CS is conducted susceptibility, RE is radiated emissions and RS is radiated susceptibility. The three digits after the letters identify the specific test method, for example RE102 or RS103.
How many test methods are in MIL-STD-461? There are 19: CE101, CE102, CE106, CS101, CS103, CS104, CS105, CS109, CS114, CS115, CS116, CS117, CS118, RE101, RE102, RE103, RS101, RS103 and RS105. Which apply depends on the platform.
What is the frequency range of RE102 and RS103? RE102 covers 10 kHz to 18 GHz. RS103 covers 2 MHz to 40 GHz, with the upper limit depending on the platform and the procuring activity.
Does MIL-STD-461H need new test equipment? No. Published reviews of 461H note that it adds no new requirements and needs no new test equipment. The main practical changes are quarter-bandwidth receiver steps, mandatory overload checks, CE101 to 20 kHz for Navy platforms, and more detailed test reports with setup photographs.
Can a reverberation chamber be used for RS103? Yes, above the chamber's lowest usable frequency. Below that frequency another method is needed, and the approach should be agreed with the procuring activity first.