Earth Resistance & Grounding Test

MEWOI Earth Resistance & Soil Resistivity Testers

MEWOI4105A / 4000 / 4000D / 4000C / 4200D / 4200 / 4300D / 4250

MEWOI stake-method earth resistance testers from the basic 3-terminal MEWOI4105A to 4-wire soil resistivity, dual-clamp and untie-free tower testers measuring up to 30kΩ and 9000kΩm.

Earth Resistance & Grounding Test
Earth Resistance / Soil Resistivity Tester
Portable Field Instrument
Enquire About This Product
MEWOI4300D earth resistance and soil resistivity tester

Overview

Stake-method earth testers inject current between the electrode under test and auxiliary spikes driven into the ground, and measure the voltage drop to calculate resistance. Unlike a clamp-on tester they work on single, isolated electrodes and new installations, and the 4-wire (Wenner) arrangement measures soil resistivity for designing an earthing system before it is installed.

The range builds up in capability. The MEWOI4105A is a simple 3-terminal tester with 20/200/2000Ω ranges. The MEWOI4000 and 4000D add 2- and 3-wire testing to 2000Ω with earth voltage and 400-set memory. The MEWOI4000C and 4200D add 4-wire soil resistivity and extend the range to 30kΩ. The MEWOI4200 and 4300D combine all of these with dual-clamp (stakeless) measurement, AC leakage current to 600A and 2000-set memory. The MEWOI4250 is built for transmission towers and substations, measuring a tower's footing resistance with four clamps without disconnecting the down-leads.

Key Specifications

ModelEarth resistanceSoil resistivityMethods / extrasMemory
MEWOI4105A20 / 200 / 2000Ω, ±(2%+0.1Ω)—3-terminal; earth voltage to 200V—
MEWOI40000.01Ω–2000Ω—2/3-wire; earth voltage 0–600V; RS232400 sets
MEWOI4000D0.01Ω–2000Ω—2/3-wire; earth voltage 0–600V; RS232400 sets
MEWOI4000C0.01Ω–30kΩ0.01Ωm–9000kΩm2/3/4-wire; earth voltage 0–600V300 sets
MEWOI4200D0.01Ω–30kΩ0.01Ωm–9000kΩm2/3/4-wire; earth voltage 0–600V300 sets
MEWOI42000.01Ω–30kΩ; dual clamp 0.01–100Ω0.01Ωm–9000kΩm2/3/4-wire, selective and dual-clamp; AC leakage 0–600A; earth voltage 0–100V2000 sets
MEWOI4300D0.01Ω–30kΩ; dual clamp 0.01–100Ω0.01Ωm–9000kΩm2/3/4-wire, selective and dual-clamp; AC leakage 0–600A; earth voltage 0–100V2000 sets
MEWOI42500.10Ω–20kΩ; 4-clamp 0.10–200Ωto 9000kΩmUntie-free tower method; AC current 1mA–500A; earth voltage 0–200V100 sets

Features

Applications

Earthing system design and commissioning; soil resistivity surveys; substation and transmission tower footing resistance; lightning protection earth testing; telecom and industrial site earthing.