Output current up to ±3A (ATS-2420C), resolution down to 20pA (ATS-2401C), four-quadrant precision current source
Current-based measurements — photodiode characterisation, low-current sensor calibration, semiconductor parameter testing — often need a source capable of extremely fine current steps, well beyond what a general-purpose current source can deliver. Aigtek's ATS-2000C Series addresses this specifically: a high-precision current source with resolution down to 20pA, built for general-purpose precision current sourcing rather than power delivery.
The range is split across three models: the ATS-2401C reaches ±1A with resolution down to 20pA, the ATS-2420C extends to ±3A with resolution down to 500pA, and the ATS-2100CF covers ±100mA with resolution down to 10nA and the tightest accuracy specification of the three. Each model steps through multiple output ranges, with Aigtek publishing resolution and one-year accuracy for every range.
The straightforward LCD panel operation keeps the instrument accessible for routine lab use, while the underlying precision specification supports the kind of exacting current-source applications — device characterisation, precision calibration, low-current reference generation — that a general bench current source isn't built to handle.


| Model | Output Current | Resolution | Digits | |
|---|---|---|---|---|
| ATS-2401C | 1A | 20pA | 5½ | Enquire |
| ATS-2420C | 3A | 500pA | 5½ | Enquire |
| ATS-2100CF | ±100mA | 10nA | Enquire |
The ATS-2401C is a four-quadrant high-precision current source with a maximum output current of ±1A and a minimum current resolution of 20pA. Output is numerically adjustable to suit the test, and the LCD panel shows device status and parameters.
| Model | ATS-2401C |
| Output Ranges (accuracy within 1 year, 25°C ±5°C, ± (% of output + offset)) | |
| Range ±1.00000μA | Resolution 20pA; accuracy ±(0.035% + 600pA) |
| Range ±10.0000μA | Resolution 200pA; accuracy ±(0.033% + 2nA) |
| Range ±100.000μA | Resolution 2nA; accuracy ±(0.031% + 20nA) |
| Range ±1.00000mA | Resolution 20nA; accuracy ±(0.034% + 200nA) |
| Range ±10.0000mA | Resolution 200nA; accuracy ±(0.045% + 2μA) |
| Range ±100.000mA | Resolution 2μA; accuracy ±(0.066% + 20μA) |
| Range ±1.00000A | Resolution 20μA; accuracy ±(0.27% + 900μA) |
Download the full technical datasheet for the ATS-2401C, published by Aigtek.
⬇ Download Datasheet (PDF) Enquire About ATS-2401C →The ATS-2420C is a four-quadrant high-precision current source with a maximum output current of ±3A and a minimum current resolution of 500pA. Output is numerically adjustable to suit the test, and the LCD panel shows device status and parameters.
| Model | ATS-2420C |
| Output Ranges (accuracy within 1 year, 25°C ±5°C, ± (% of output + offset)) | |
| Range ±10.0000μA | Resolution 500pA; accuracy ±(0.033% + 2nA) |
| Range ±100.000μA | Resolution 5nA; accuracy ±(0.03% + 20nA) |
| Range ±1.00000mA | Resolution 50nA; accuracy ±(0.034% + 200nA) |
| Range ±10.0000mA | Resolution 500nA; accuracy ±(0.045% + 2μA) |
| Range ±100.000mA | Resolution 5μA; accuracy ±(0.066% + 20μA) |
| Range ±1.00000A | Resolution 50μA; accuracy ±(0.067% + 900μA) |
| Range ±3.00000A | Resolution 200μA; accuracy ±(0.059% + 2.7mA) |
Download the full technical datasheet for the ATS-2420C, published by Aigtek.
⬇ Download Datasheet (PDF) Enquire About ATS-2420C →The ATS-2100CF is a four-quadrant high-precision current source with a maximum output current of ±100mA and a minimum current resolution of 10nA. Output is numerically adjustable to suit the test, and the LCD panel shows device status and parameters.
| Model | ATS-2100CF |
| Output Ranges (accuracy within 1 year, 25°C ±5°C, ± (% of output + offset)) | |
| Range ±1mA | Resolution 10nA; accuracy ±(0.003% + 0.05μA) |
| Range ±10mA | Resolution 100nA; accuracy ±(0.005% + 0.5μA) |
| Range ±100mA | Resolution 1μA; accuracy ±(0.01% + 5μA) |
Download the full technical datasheet for the ATS-2100CF, published by Aigtek.
⬇ Download Datasheet (PDF) Enquire About ATS-2100CF →Photodiode and other low-current sensor characterisation, semiconductor leakage current testing, and precision calibration of sensitive current-measurement instruments all operate at current levels where coarse resolution would swamp the actual signal being characterised — 20pA resolution lets the ATS-2000C source current accurately at this scale.
Each model steps through multiple output ranges, from microamps to its full-scale current, with finer resolution on the lower ranges. No single model covers the whole span: choose the ATS-2401C for the finest resolution (20pA, up to ±1A), the ATS-2420C for the highest current (up to ±3A, from 500pA resolution), or the ATS-2100CF for the tightest accuracy up to ±100mA.
Its precision-first specification and general-purpose current-sourcing design make it well suited to both lab characterisation work and calibration tasks; its straightforward panel operation also supports it being used in a more repetitive production or QA testing context where operator simplicity matters alongside accuracy.
See Aigtek's technical documentation for the ATS-2000C series →