Bandwidth (-3dB) up to DC~300kHz, max output power 1000Wp, CV and CC operation
General-purpose power amplification of AC and DC signals — driving power-type loads without the extreme voltage of Aigtek's dedicated high-voltage series, but with more output power than a lab signal amplifier — covers a broad and practical middle ground in test and drive applications. Aigtek's ATA-3000 Series addresses this segment directly, amplifying AC and DC signals up to 1000Wp of maximum output power.
The ATA-3040C, ATA-3080C and ATA-3090C share a DC~120kHz bandwidth with digitally set gain. The ATA-3100B extends the range to 300kHz and adds constant-current operation, with 280Vp-p, 45Ap continuous and 800VA output for coil, transformer core loss and magnetic particle imaging work.
Bandwidth to 120kHz (-3dB), or 300kHz on the ATA-3100B, gives the ATA-3000 solid dynamic response for its power class, and numerically controlled voltage gain adjustment supports precise, repeatable configuration of output scaling. As a general power amplifier rather than a specialised high-voltage or wide-bandwidth instrument, the ATA-3000 fits applications where driving a power-type load at moderate frequency is the core requirement, without needing the specialised characteristics (extreme voltage, extended bandwidth, PZT-specific matching) that other series in the range are built around.
This positions the ATA-3000 as a practical general-purpose choice — where an application's requirements are straightforward power amplification within a moderate frequency range, it covers that need without the added cost of specification the application doesn't actually use.


| Model | Bandwidth (-3dB) | Voltage | Current | Power | Output | |
|---|---|---|---|---|---|---|
| ATA-3040C Power Amplifier | DC~120kHz | 100Vp-p(±50Vp) | 10Ap | 500Wp | Single | Enquire |
| ATA-3080C Power Amplifier | DC~120kHz | 160Vp-p(±80Vp) | 10Ap | 800Wp | Differential | Enquire |
| ATA-3090C Power Amplifier | DC~120kHz | 100Vp-p(±50Vp) | 20Ap | 1000Wp | Single | Enquire |
| ATA-3100B Power Amplifier | DC~300kHz (±20Vp) DC~50kHz (±140Vp) | 280Vp-p(±140Vp) | 45Ap (52Ap pulsed) | 800VA | Single | Enquire |
The ATA-3040C is a power amplifier capable of amplifying both AC and DC signals, with a maximum output power of 500Wp to drive high-power loads. Gain is digitally adjustable with one-click saving of common settings, it is compatible with mainstream signal generators, and the wide-range power supply accommodates different regional power standards.
| Model | ATA-3040C |
| Output Type | Single-ended Output |
| Bandwidth (-3dB) | DC~120kHz |
| Maximum Output Voltage | 100Vp-p (±50Vp) |
| Maximum Output Current | 5Ap (DC~50Hz) 10Ap (>50Hz) |
| Maximum Output Power | 500Wp |
| Fuse | 10A/250V |
| Voltage Gain | x0~30 (0.1 step/1 step) |
| Load RL Upper Limit | ≥9.9Ω (DC~50Hz) ≥4.9Ω (>50Hz) |
| DC Bias Adjustment | ±50V (0.1V step/1V step) |
| Output Impedance | 0.1Ω |
| Input Impedance | 50Ω / 100kΩ |
| Input Amplitude | 0~10Vp-p MAX |
| Output Voltage Error | ≤±3% FS @ 1kHz |
| Voltage Monitoring | 20mV/V (±5% @ Output, FS) |
| Current Monitoring | 0.1V/A (±5% @ Output, FS) |
| Slew Rate | ≥26.6V/μs |
| Total Harmonic Distortion (THD) | ≤0.1% @ 1kHz, 100Vp-p |
| Output Voltage Drift | ≤±0.05V |
| Ripple | ≤0.01Vrms |
| Output Interface | 4mm Banana socket |
| Protection | Short Circuit, Over Voltage and Over Temperature Protection |
| Signal Ground | Connected to chassis and power line ground |
| Others | |
| Power Supply Voltage | AC110~240V, 50/60Hz |
| Operating Temperature | 0°C~45°C |
| Storage Temperature | -20°C~50°C |
| Working Humidity | ≤80% RH, non-condensing |
| Warranty | 1 year |
| Dimensions | 440×149×535mm (W×H×D) |
Download the full technical datasheet for the ATA-3040C Power Amplifier, published by Aigtek.
⬇ Download Datasheet (PDF) Enquire About ATA-3040C →The ATA-3080C is a power amplifier capable of amplifying both AC and DC signals, with a maximum output power of 800Wp to drive high-power loads. Gain is digitally adjustable with one-click saving of common settings, it is compatible with mainstream signal generators, and the wide-range power supply accommodates different regional power standards.
| Model | ATA-3080C |
| Output Type | Single-ended Output |
| Bandwidth (-3dB) | DC~120kHz |
| Maximum Output Voltage | 160Vp-p (±80Vp) |
| Maximum Output Current | 5Ap (DC~50Hz) 10Ap (>50Hz) |
| Maximum Output Power | 800Wp |
| Fuse | 10A/250V |
| Voltage Gain | x0~60 (0.1 step/1 step) |
| Load RL Upper Limit | ≥15.9Ω (DC~50Hz) ≥7.9Ω (>50Hz) |
| DC Bias Adjustment | ±80V (0.1V step/1V step) |
| Output Impedance | 0.1Ω |
| Input Impedance | 50Ω / 100kΩ |
| Input Amplitude | 0~10Vp-p MAX |
| Output Voltage Error | ≤±3% FS @ 1kHz |
| Voltage Monitoring | 20mV/V (±5% @ Output, FS) |
| Current Monitoring | 0.1V/A (±5% @ Output, FS) |
| Slew Rate | ≥42.6V/μs |
| Total Harmonic Distortion (THD) | ≤0.1% @ 1kHz, 100Vp-p |
| Output Voltage Drift | ≤±0.05V |
| Ripple | ≤0.01Vrms |
| Output Interface | 4mm Banana socket |
| Protection | Short Circuit, Over Voltage and Over Temperature Protection |
| Signal Ground | Connected to chassis and power line ground |
| Others | |
| Power Supply Voltage | AC110~240V, 50/60Hz |
| Operating Temperature | 0°C~45°C |
| Storage Temperature | -20°C~50°C |
| Working Humidity | ≤80% RH, non-condensing |
| Warranty | 1 year |
| Dimensions | 440×149×535mm (W×H×D) |
Download the full technical datasheet for the ATA-3080C Power Amplifier, published by Aigtek.
⬇ Download Datasheet (PDF) Enquire About ATA-3080C →The ATA-3090C is a power amplifier capable of amplifying both AC and DC signals, with a maximum output power of 1000Wp to drive high-power loads. Gain is digitally adjustable with one-click saving of common settings, it is compatible with mainstream signal generators, and the wide-range power supply accommodates different regional power standards.
| Model | ATA-3090C |
| Output Type | Single-ended Output |
| Bandwidth (-3dB) | DC~120kHz |
| Maximum Output Voltage | 100Vp-p (±50Vp) |
| Maximum Output Current | 10Ap (DC~50Hz) 20Ap (>50Hz) |
| Maximum Output Power | 1000Wp |
| Fuse | 10A/250V |
| Voltage Gain | x0~30 (0.1 step/1 step) |
| Load RL Upper Limit | ≥4.9Ω (DC~50Hz) ≥2.4Ω (>50Hz) |
| DC Bias Adjustment | ±50V (0.1V step/1V step) |
| Output Impedance | 0.1Ω |
| Input Impedance | 50Ω / 100kΩ |
| Input Amplitude | 0~10Vp-p MAX |
| Output Voltage Error | ≤±3% FS @ 1kHz |
| Voltage Monitoring | 20mV/V (±5% @ Output, FS) |
| Current Monitoring | 0.05V/A (±5% @ Output, FS) |
| Slew Rate | ≥26.6V/μs |
| Total Harmonic Distortion (THD) | ≤0.1% @ 1kHz, 100Vp-p |
| Output Voltage Drift | ≤±0.05V |
| Ripple | ≤0.01Vrms |
| Output Interface | 4mm Banana socket |
| Protection | Short Circuit, Over Voltage and Over Temperature Protection |
| Signal Ground | Connected to chassis and power line ground |
| Others | |
| Power Supply Voltage | AC110~240V, 50/60Hz |
| Operating Temperature | 0°C~45°C |
| Storage Temperature | -20°C~50°C |
| Working Humidity | ≤80% RH, non-condensing |
| Warranty | 1 year |
| Dimensions | 440×149×535mm (W×H×D) |
Download the full technical datasheet for the ATA-3090C Power Amplifier, published by Aigtek.
⬇ Download Datasheet (PDF) Enquire About ATA-3090C →
The ATA-3100B is a power amplifier for both AC and DC signals, with up to 800VA of output power, 280Vp-p and 45Ap continuous (52Ap pulsed) to drive coils, transformers and other power-type loads. It runs in constant-voltage (CV) or constant-current (CC) mode, and its bandwidth extends to 300kHz at ±20Vp, 200kHz at ±40Vp and 50kHz at full ±140Vp swing. Gain is set with a front-panel rotary knob, so it pairs simply with any standard signal generator, and the wide-range mains input suits power standards worldwide.
| Model | ATA-3100B |
| Output Type | Single-ended Output |
| Operating Modes | Constant-voltage (CV) and constant-current (CC) |
| Bandwidth (-3dB) | DC~300kHz (±20Vp) DC~200kHz (±40Vp) DC~50kHz (±140Vp) |
| Maximum Output Voltage | 280Vp-p (±140Vp) |
| Maximum Continuous Current | 45Ap |
| Maximum Pulsed Current | 52Ap (20% duty @ 40ms) |
| Maximum Output Power | 800VA |
| Fuse | 10A/250V |
| Voltage Gain | x20, adjustable 0~100% |
| Output Resistance | 0.04Ω |
| Input Resistance | 10kΩ |
| Input Amplitude | 0~20Vp-p MAX |
| Output Voltage Error | ≤±3% FS @ 1kHz |
| Total Harmonic Distortion (THD) | ≤0.5% @ 1kHz, 140Vp-p |
| Input Interface | BNC |
| Output Interface | 3-position barrier terminal block |
| Protection | Overcurrent, Over Voltage and Over Temperature Protection |
| Pushbuttons | Run, Stop, Reset |
| LED Indicators | Work, Standby, Fault, Overvoltage, Overload, Overtemperature |
| Signal Ground | Connected to chassis and power line ground (PE) |
| Others | |
| Power Supply Voltage | AC110~240V, 50/60Hz |
| Operating Temperature | 0°C~45°C |
| Storage Temperature | -20°C~50°C |
| Working Humidity | ≤80% RH, non-condensing |
| Warranty | 1 year |
| Dimensions | 440×104×528mm (W×H×D) |
| Accessories | Power cord, BNC cable, red/black output lead set, spare fuse, 2× 2.7Ω/2W resistors, user manual, user guide, certificate of conformance, calibration certificate |
Pulse figures are 40ms at 20% duty cycle; 5min and 1h figures are at 100% duty cycle. Choose the mode that matches your load impedance: high-voltage for 4–16Ω, medium-level for 0.5–4Ω, high-current for 0.5–1Ω.
| High-Voltage Mode | |
| 16Ω load | Peak 158Vp / 9.8Ap (pulse, 5min and 1h); RMS 112Vrms / 6.9Arms, 773VA for 1h |
| 8Ω load | Peak 154Vp / 19Ap (pulse), 136Vp / 16Ap (5min, 1h); RMS 96Vrms / 11.5Arms, 1104VA for 1h |
| 4Ω load | Peak 124Vp / 31Ap (pulse), 108Vp / 25.7Ap (5min), 61Vp / 14.5Ap (1h); RMS 43Vrms / 10.3Arms, 443VA for 1h |
| 2Ω load | Peak 98Vp / 49Ap (pulse only) |
| Medium-Level Mode | |
| 4Ω load | Peak 72Vp / 18Ap (pulse), 69Vp / 16.4Ap (5min, 1h); RMS 49Vrms / 11.6Arms, 568VA for 1h |
| 2Ω load | Peak 61Vp / 30Ap (pulse), 57Vp / 26.2Ap (5min, 1h); RMS 40Vrms / 18.5Arms, 740VA for 1h |
| 1Ω load | Peak 47Vp / 47Ap (pulse), 43Vp / 39.6Ap (5min), 21Vp / 21Ap (1h); RMS 15Vrms / 14.8Arms, 222VA for 1h |
| 0.5Ω load | Peak 26Vp / 52Ap (pulse only) |
| High-Current Mode | |
| 1Ω load | Peak 29Vp / 29Ap (5min, 1h); RMS 20.5Vrms / 20.5Arms, 420VA for 1h |
| 0.75Ω load | Peak 26Vp / 34Ap (5min, 1h); RMS 18Vrms / 24Arms, 432VA for 1h |
| 0.5Ω load | Peak 22.7Vp / 45Ap (5min, 1h); RMS 16Vrms / 32Arms, 512VA for 1h |
Ask us for the full ATA-3100B datasheet, including the complete AC output tables.
Enquire About ATA-3100B →General power-type loads requiring AC or DC signal amplification up to 1000Wp — a broad category covering many standard power amplification test and drive applications that don't call for the extreme voltage or specialised load-matching of Aigtek's more specialised series.
The ATA-300 series reaches a higher maximum output power, up to 4000Wp. Where an application needs substantially more raw output power, the ATA-300 is the appropriate choice; where up to 1000Wp at up to 120kHz is sufficient, or 800VA and 45Ap at up to 300kHz with the ATA-3100B, the ATA-3000 covers the requirement.
Numerical control gives precise, repeatable gain settings that can be dialled in exactly and reproduced consistently across test sessions, avoiding the drift or imprecision that can come with a purely manual analog gain adjustment.
See Aigtek's technical documentation for the ATA-3000 series →