LISUN WDT-1 terminal conductor damage testers to IEC 60884-1 Clause 12.2.5, IEC 60669-1, IEC 60998-2-2 and UL 486A-B, with rotating bushing and weights.
Enquire About This Product
Terminals in plugs, sockets, switches and connectors must clamp a wire firmly without cutting or damaging it. Standards test this by clamping a conductor in the terminal, passing it through a bushing below with a weight hanging on it, and rotating the bushing so the conductor is flexed at the terminal, then checking that it has not slipped out or broken.
The WDT-1 series performs this test with a lead screw and guide rail mechanism. Rotation speed (5 to 12rpm), test time and number of turns are preset, and the machine stops with an audible alarm when the count is reached. Three versions cover different standards and conductor sizes: the WDT-1 and WDT-1A for IEC 60884-1, IEC 60669-1 and IEC 60998-2-2, and the WDT-1B with weights up to 45.4kg and bushings up to 31.8mm for UL 486A-B.
| Specification | WDT-1 | WDT-1A | WDT-1B |
|---|---|---|---|
| Standards | IEC 60884-1 Clause 12.2.5 | IEC 60998-2-2 Clause 10.105; IEC 60669-1 Clause 12.2 | IEC 60884-1; IEC 60669-1; UL 486A-B Clause 9.3.2 |
| Weights | 0.3, 0.4, 0.7, 0.9, 1.4, 2.0kg | 0.2 to 6.8kg (10 weights) | 0.3 to 45.4kg (18 weights) |
| Bushing diameters | 6.5, 9.5mm | 6.4, 6.5, 9.5, 13, 14.5mm | 6.5~31.8mm (13 sizes) |
| Rotation diameter | 75mm | 75mm, 76mm | |
| Height | 240~300mm | 240~640mm | |
| Speed | 5~12rpm, adjustable | ||
| Test time | 0~99min 59s | ||
| Turns | 0~999,999 | ||
| Stations | 1 | ||
| Control | Electrical control, push-button operation | ||
The WDT-1 or WDT-1A for IEC accessories and connectors; the WDT-1B if you test to UL 486A-B, which needs heavier weights and larger bushings.