LISUN SW series cord flexing testers to IEC 60335-1 Clause 25.14, IEC 60884-1 Clause 23.4 and IEC 60745-1: 1, 2 or 6 stations, servo drive, load to 20A.
Enquire About This Product
The point where a power cord enters an appliance, plug or tool is flexed many times in use and is a common place for conductors to break. IEC 60335-1 Clause 25.14, IEC 60884-1 Clause 23.4 and IEC 60745-1 Clause 24.12 test it by swinging the sample back and forth with a weight on the cord while current flows through it.
The SW series do this with a servo motor under PLC control and a 7-inch touch screen. Bending angle (up to ±90°), rate (0 to 60 per minute) and count are set on screen, the cord carries a load current of 0 to 20A, and the tester stops automatically when the set count is reached or when a conductor breaks and current stops. Models have one, two or six stations, each with 5N, 10N and 20N weights.
| Specification | SW-1 | SW-2 | SW-6 |
|---|---|---|---|
| Stations | 1 | 2 | 6 |
| Weights | 1 set: 5N, 10N, 20N | 2 sets: 5N, 10N, 20N | 6 sets: 5N, 10N, 20N |
| Control | PLC with 7-inch touch screen | ||
| Drive | Servo motor | ||
| Clamping | Mechanical, adjustable position | ||
| Bending angle | 0~360° adjustable (±30°, ±45°, ±60°, ±90° settings) | ||
| Rate | 0~60 per minute | ||
| Count | 0~999,999 | ||
| Load current | 0~20A adjustable | ||
| Failure detection | Stops when current is interrupted | ||
Current flows through the cord during the test; when a conductor breaks and current stops, the tester stops and records the count.