LISUN
Home
/
Electrical Safety Test Equipment

SW Series Power Cord Flex Tester (IEC 60335-1 25.14) – LISUN

SW-1 / SW-2 / SW-6

LISUN SW series cord flexing testers to IEC 60335-1 Clause 25.14, IEC 60884-1 Clause 23.4 and IEC 60745-1: 1, 2 or 6 stations, servo drive, load to 20A.

Electrical Safety Test Equipment
Plug, Switch & Cable Test
Bench-top Tester
IEC 60335-1:2023 Clause 25.14; IEC 60884-1:2022 Clause 23.4 and Figure 28; IEC 60745-1 Clause 24.12; GB/T 4706.1-2024; GB/T 2099.1-2021; GB/T 3883.1-2014
Enquire About This Product
LISUN SW Series Power Cord Flex Tester (IEC 60335-1 25.14)

Overview

The point where a power cord enters an appliance, plug or tool is flexed many times in use and is a common place for conductors to break. IEC 60335-1 Clause 25.14, IEC 60884-1 Clause 23.4 and IEC 60745-1 Clause 24.12 test it by swinging the sample back and forth with a weight on the cord while current flows through it.

The SW series do this with a servo motor under PLC control and a 7-inch touch screen. Bending angle (up to ±90°), rate (0 to 60 per minute) and count are set on screen, the cord carries a load current of 0 to 20A, and the tester stops automatically when the set count is reached or when a conductor breaks and current stops. Models have one, two or six stations, each with 5N, 10N and 20N weights.

Key Specifications

SpecificationSW-1SW-2SW-6
Stations126
Weights1 set: 5N, 10N, 20N2 sets: 5N, 10N, 20N6 sets: 5N, 10N, 20N
ControlPLC with 7-inch touch screen
DriveServo motor
ClampingMechanical, adjustable position
Bending angle0~360° adjustable (±30°, ±45°, ±60°, ±90° settings)
Rate0~60 per minute
Count0~999,999
Load current0~20A adjustable
Failure detectionStops when current is interrupted

Features

Applications

Frequently asked questions

How does it detect a failure?

Current flows through the cord during the test; when a conductor breaks and current stops, the tester stops and records the count.

Related Reading