LISUN LSTMR-103 measures motor and transformer winding temperature rise by the resistance method on 1 or 2 windings, 0.5 to 10000Ω, ±0.2%, RS232/485 and USB.

Electrical Safety Test Equipment
Transformers & Regulators
Bench-top Instrument
IEC 60034-1:2017; IEC 61558-1:2017; IEC 61558-2-6:2017; GB/T 12350-2019; GB/T 1094.2-2013; GB/T 19212.1; GB/T 19212.16
Enquire About This Product
LISUN LSTMR-103 Winding Temperature Rise Tester

Overview

The temperature rise of a motor or transformer winding is normally found by the resistance method: the winding's cold resistance is measured, the product is run until hot, and the hot resistance gives the average winding temperature. Measuring while the winding is still energised avoids the cooling that occurs after switch-off.

The LSTMR-103 measures cold and hot resistance on one or two windings at the same time and calculates the temperature rise. Its colour LCD shows cold resistance, hot resistance, temperature rise and test time for both windings, ranges switch automatically, and data can be read by a PC over RS232 or RS485 or saved to a USB drive at set intervals.

Key Specifications

ItemSpecification
Resistance range0.500~10000Ω
Accuracy, 0.500~99.99Ω±0.2% ±5 digits
Accuracy, 99.99~2000Ω±0.2% ±2 digits
Accuracy, 2000~10000Ω±0.2% ±1 digit
Windings1 or 2 at the same time
InterfacesRS232/RS485, USB drive
SupplyAC 220V ±10%, 50Hz
Size / weight330 × 400 × 150mm; 9kg

Features

Applications

Frequently asked questions

How is temperature rise calculated?

From the change in winding resistance between cold and hot, using the temperature coefficient of copper or aluminium as the standards specify.