Overview

Plugs must withstand being stepped on or squeezed without exposing live parts. IEC 60884-1 includes two compression tests using the apparatus of Figure 6: one at elevated temperature for plugs with partially insulated pins (Clause 10.2) and one at room temperature for the plug body (Clause 24.6).

The LS-B08 applies the force with weights: a 150N main weight for the Clause 10.2 test at 35 ±2°C, and an additional 150N for 300N in the Clause 24.6 test at 23 ±2°C. The plug sits on a steel base more than 5mm thick and 18mm wide, and a threaded mechanism raises and lowers the load. For the heated test it is used inside an oven such as the LISUN GW-225.

Key Specifications

ItemSpecification
Main weight150N
Additional weight150N
Clause 10.2 test150N at 35 ±2°C (40°C in GB/T 2099.1)
Clause 24.6 test300N at 23 ±2°C