Home /
Environmental Test Equipment

Corrosion & Accelerated Aging Test Chambers

Salt Spray, HAST Pressure-Cooker, and Ozone Aging Test Chambers

Corrosion and material-degradation testing covers a different set of failure modes to temperature/humidity cycling — electrochemical corrosion of metal parts, elastomer and polymer degradation, and moisture ingress under pressure rather than at atmospheric conditions. Each requires a purpose-built chamber rather than a general-purpose environmental chamber run at extended duration.

Sonacme's range covers combined temperature/humidity/salt spray chambers for salt spray, Prohesion and automotive cyclic corrosion testing, HAST (Highly Accelerated Stress Test) chambers for accelerated moisture-related failure testing on semiconductor and electronic packages, and an ozone aging chamber for evaluating rubber and polymer degradation under ozone exposure. The salt spray corrosion chamber line spans four volumes from 480L to 8000L.

Corrosion & Accelerated Aging Test Chambers
Inquire About This Range →
Sonacme temperature humidity salt spray corrosion test chamber

Salt Spray & Corrosion Test Chambers (SSC Series)

Temperature/humidity salt spray and cyclic corrosion testing across four capacities from 480L to 8000L.
Enquire About This Series →

Technical Specifications

Humidity range20-98%RH
Salt spray solution5% sodium chloride, optionally with 0.26g/L copper dichloride (CuCl₂·2H₂O)
Spray rate1.0-2.0ml/80cm²/h, averaged over a minimum 16-hour collection
Test methods supportedSalt spray, Prohesion cycle tests (salt spray and dry phases) and multi-step automotive cyclic corrosion tests (salt spray, humidity/condensation and dry phases)

Which model do I need?

The deciding factors are the temperature range your cyclic corrosion profile needs and the test space. The SSC/120 and SSC/200 run −20 to +80°C (lower limit chosen as grade A, B or C), the SSC/8000 walk-in runs −40 to +80°C, and only the SSC/1800 reaches −70 to +180°C. All four share 20–98%RH humidity and the same spray rate. Click a model for its full specifications.

ModelTemperature rangeVolumeTest space W×H×D (mm)External size W×H×D (mm)
SSC/120(TH)−20 to +80°C480L1200×850×5002200×1200×1450
SSC/200(TH)−20 to +80°C1440L2000×1200×6003000×1650×1600
SSC/1800(TH)−70 to +180°C1800L1800×1000×10002800×1450×2150
SSC/8000(TH)−40 to +80°C8000L2000×2000×32003200×2350×2800

Model specifications

480L

SSC/120(TH) Corrosion Chamber

Temperature range−20 to +80°C (grade A: 25°C, B: 0°C, C: −20°C)
Humidity range20–98%RH
Volume480L
Test space (W×H×D)1200×850×500mm
External size (W×H×D)2200×1200×1450mm
Salt solution5% NaCl, optionally with 0.26g/L CuCl₂·2H₂O
Spray rate1.0–2.0ml/80cm²/h (16h minimum collection)
Enquire about SSC/120(TH) →
1440L

SSC/200(TH) Corrosion Chamber

Temperature range−20 to +80°C (grade A: 25°C, B: 0°C, C: −20°C)
Humidity range20–98%RH
Volume1440L
Test space (W×H×D)2000×1200×600mm
External size (W×H×D)3000×1650×1600mm
Salt solution5% NaCl, optionally with 0.26g/L CuCl₂·2H₂O
Spray rate1.0–2.0ml/80cm²/h (16h minimum collection)
Enquire about SSC/200(TH) →
1800L

SSC/1800(TH) Corrosion Chamber

Temperature range−70 to +180°C
Humidity range20–98%RH
Volume1800L
Test space (W×H×D)1800×1000×1000mm
External size (W×H×D)2800×1450×2150mm
Salt solution5% NaCl, optionally with 0.26g/L CuCl₂·2H₂O
Spray rate1.0–2.0ml/80cm²/h (16h minimum collection)
Enquire about SSC/1800(TH) →
8000L

SSC/8000(TH) Corrosion Chamber

Temperature range−40 to +80°C
Humidity range20–98%RH
Volume8000L
Test space (W×H×D)2000×2000×3200mm
External size (W×H×D)3200×2350×2800mm
Salt solution5% NaCl, optionally with 0.26g/L CuCl₂·2H₂O
Spray rate1.0–2.0ml/80cm²/h (16h minimum collection)
Enquire about SSC/8000(TH) →

HAST Accelerated Aging Chambers (S/HAST Series)

Pressurised, high-temperature/humidity sealing and reliability testing for semiconductor and electronic packages.
Enquire About This Series →

Technical Specifications

Temperature range105°C to 143°C
Pressure range+0.2 to +3.5 kg/cm² above atmospheric, model dependent
Humidity range65-100%RH
Typical applicationUnsaturated/saturated HAST sealing and reliability testing for IC packages, PCBs, LEDs, semiconductors and magnetic components

Which model do I need?

All three run 105–143°C and 65–100%RH. Choose by vessel size for your samples and boards, and by maximum pressure: the larger vessels go higher above atmospheric. Click a model for its full specifications.

ModelInner vessel Ø×depth (mm)Pressure (above atmospheric)External size W×D×H (mm)
S/HAST/250/AØ250×450+0.2 to 2.0 kg/cm²560×1050×1250
S/HAST/300/AØ300×450+0.2 to 3.0 kg/cm²660×1050×1250
S/HAST/400/AØ400×500+0.2 to 3.5 kg/cm²760×1150×1350

Model specifications

Ø250×450mm

S/HAST/250/A HAST Chamber

Inner vessel (Ø×depth)Ø250×450mm
External size (W×D×H)560×1050×1250mm
Pressure rangeNormal pressure +0.2 to 2.0 kg/cm²
Temperature range105.0 to 143.0°C
Humidity range65.0 to 100.0%RH
Enquire about S/HAST/250/A →
Ø300×450mm

S/HAST/300/A HAST Chamber

Inner vessel (Ø×depth)Ø300×450mm
External size (W×D×H)660×1050×1250mm
Pressure rangeNormal pressure +0.2 to 3.0 kg/cm²
Temperature range105.0 to 143.0°C
Humidity range65.0 to 100.0%RH
Enquire about S/HAST/300/A →
Ø400×500mm

S/HAST/400/A HAST Chamber

Inner vessel (Ø×depth)Ø400×500mm
External size (W×D×H)760×1150×1350mm
Pressure rangeNormal pressure +0.2 to 3.5 kg/cm²
Temperature range105.0 to 143.0°C
Humidity range65.0 to 100.0%RH
Enquire about S/HAST/400/A →

Ozone Aging Test Chamber (SO/150)

Compact chamber for ozone crack-resistance testing of rubber and elastomer materials.
Enquire About This Series →

Technical Specifications

ModelSO/150
Internal dimensions (W×H×D)500x600x500mm
External dimensions (W×H×D)1150x1500x750mm
Temperature rangeAmbient +10°C to +60°C
Ozone concentration0-1500 pphm, adjustable, ≤10% deviation
Power supply3-5kW
Frequently Asked Questions
What corrosion test methods do the SSC chambers run?
Salt spray testing, simple cycle tests such as the Prohesion cycle (salt spray and dry conditions), and more complex multi-step automotive cyclic corrosion tests combining salt spray, humidity or condensation, and dry phases. The salt solution is 5% sodium chloride, optionally with copper dichloride added.
What is HAST testing used for?
Highly Accelerated Stress Test (HAST) exposes sealed electronic packages — ICs, PCBs, LEDs, semiconductors — to elevated temperature, pressure and humidity simultaneously, to accelerate moisture-related failure modes that would otherwise take months to appear under standard damp-heat testing.
What's the difference between salt spray and HAST?
Salt spray tests surface and coating corrosion resistance under atmospheric pressure. HAST pressurises the chamber to drive moisture into sealed packages far faster than normal humidity testing, targeting internal sealing and reliability rather than external corrosion.
Send an Enquiry →Send an Enquiry →

Related Reading

Read: Salt Spray Testing — NSS, AASS, and CASS Compared