A programmable AC power source lets you test a product on any mains supply in the world, and on supplies that are deliberately imperfect, without changing your building’s power. Choosing one comes down to six questions. Answer them in order and the right class of source usually becomes obvious.


1. Single Phase or Three Phase?

Match the phase configuration to the product, and to the markets it sells into. Many sources can be configured as single-phase or three-phase, which helps if you test both kinds of product. If you only ever test single-phase appliances, a dedicated single-phase source is simpler and cheaper.


2. Size the Power, Then Check Peak Current

AC sources are rated in VA (apparent power), not watts. A product with a poor power factor draws more VA than its wattage suggests, so size from VA with margin.

Then check peak current and crest factor. Switch-mode power supplies, motors and transformers draw large inrush and peaky current. A source that can only deliver a crest factor of around 1.4 may limit or distort at switch-on even though its rms rating looks big enough. If your products have rectifier front ends, look for a crest factor of 3 or more.


3. Confirm the Frequency Range

ApplicationFrequency needed
Global product compliance50 Hz and 60 Hz, with some variation either side
Aircraft and avionics (MIL-STD-704, DO-160)400 Hz, often with variable frequency ranges
Motors, drives and special equipmentWider ranges, sometimes up to several hundred Hz or more

For aerospace work, see our guides to 400 Hz ground power and MIL-STD-704 and DO-160 Section 16/17 AC power testing.


4. Decide What Waveforms and Disturbances You Need

A basic source delivers a clean sine wave at a set voltage and frequency. Compliance and robustness testing often needs more:


5. AC Source or Grid Simulator?

A conventional AC source only delivers power. If your product feeds power back, such as a PV inverter, battery inverter, EV charger with vehicle-to-grid, or regenerative drive, you need a regenerative grid simulator that can absorb power and return it to the grid. Grid simulators also offer the fast dynamics needed for grid code testing (LVRT/HVRT) and power hardware-in-the-loop work. See our regenerative grid simulators.


6. Measurement, Control and Installation


Quick Selection Checklist

  1. Single or three phase
  2. VA rating with margin, plus peak current and crest factor
  3. Frequency range, including 400 Hz if needed
  4. Dips, harmonics, DC and arbitrary waveform capability
  5. Source only, or regenerative grid simulator
  6. Measurement, interfaces, isolation and site power

Want a recommendation? Send us your product and test standard and we’ll suggest the right source.


Frequently Asked Questions

What is the difference between an AC power source and a frequency converter? A frequency converter is built to supply a fixed different frequency, such as 60 Hz or 400 Hz, to equipment in continuous use. A programmable AC source is built for testing, with adjustable voltage, frequency and waveforms. See the Preen AFC frequency converter guide.

Can I use a variac or isolation transformer instead? Only for simple voltage adjustment at mains frequency. They cannot change frequency, create dips or harmonics, or measure the output, which compliance testing needs.

Which Preen AC source is right for a small lab? Compact single-phase and three-phase units suit most bench and compliance work. Our guide to Preen AFV-S vs AFV-P compares the two compact ranges.