LISUN walk-in temperature and humidity room, 4000 × 3000 × 2200mm working space: −30 to +120°C, 20–95%RH, ±0.5°C, IEC 60068-2-1, 2-2, 2-30 and 2-78.
Enquire About This Product
The LISUN walk-in temperature and humidity chamber is a room-sized test space for large products, complete assemblies and batches of samples that will not fit in a cabinet chamber. It runs cold, dry heat and damp heat tests, steady and cyclic, as well as low-temperature storage, for electrical and electronic products, appliances, instruments, plastics and PVC, components, optical fibre, crystals, precision inductors, PCBs and LCDs. Quality control departments, testing bodies, research institutes and universities use it for reliability and quality testing.
The standard working space is 4000mm deep, 3000mm wide and 2200mm high, with a floor rated for at least 600kg. Other sizes can be built.
The chamber is assembled before delivery from 100mm insulated panels with rigid polyurethane foam. The inside walls, roof and floor are SUS304 stainless steel and the outside is plastic-coated cold-rolled steel. Double doors 2000mm wide and 2000mm high open from inside and outside, with an anti-lock safety device so nobody can be shut in. Each door has a heated, multi-layer glass observation window that clears condensation automatically, and silicone seals with anti-frost heating. Explosion-proof lights inside are switched from the control panel, and a Ø100mm cable port with a silicone plug is provided.
A centrifugal fan blows air down from the top and returns it at the bottom for even temperature without dead spots. Heating is by an independent hot-air system whose power is set automatically by the controller to suit the load, and humidity comes from a stainless steel shallow-tray evaporative humidifier.
| Parameter | Value |
|---|---|
| Working space (D × W × H) | 4000 × 3000 × 2200mm |
| External size (D × W × H) | 4600 × 4200 × 2580mm approx. |
| Temperature range | −30 to +120°C (no load) |
| Humidity range | 20–95%RH |
| Temperature fluctuation | ±0.5°C |
| Temperature deviation | ≤±2°C |
| Temperature uniformity | ≤2°C |
| Heating / cooling rate | About 0.5°C/min average (no load) |
| Humidity deviation | −3 to +2%RH above 75%RH; ±5%RH at or below 75%RH (with load) |
| Humidity fluctuation | ≤±3%RH (with load) |
| Resolution | 0.01°C; 0.1%RH |
| Air speed | 0.3m/s |
| Floor load | Uniform ≥600kg/m², total ≥1000kg |
| Doors | Double, 2000 × 2000mm, 2 observation windows |
| Timer | 0–9999h |
| Noise | ≤75dB |
| Power | 380V, 50Hz |
Yes. Walk-in chambers are built to order, and the working space, temperature range and humidity range can be adapted to your needs.
The standard chamber averages about 0.5°C/min with no load. Ask us if you need faster change rates or heavy heat loads.