LISUN LSP-VARC pure sine wave AC sources, 500VA or 1kVA, 2–300V, 45–65Hz, THD ≤0.3%, built-in power meter; Pst versions for IEC TR 61547-1 flicker.
Enquire About This Product
Accurate lamp, driver and appliance measurements need a clean, stable supply that does not change with the local mains. The LSP-VARC series are high-precision pure sine wave AC sources with very low harmonic distortion (0.3% or less), voltage and frequency stability within 0.1% and 0.05% over 30 minutes, and a near-zero internal resistance design.
A built-in meter shows output voltage, current, power, power factor and frequency on a large LCD, so the source doubles as a power meter. Protection covers short circuit, over-current, over-voltage, over-power and over-temperature. Over RS232/RS485 it works with LISUN's LSG goniophotometers, LPCE-2 integrating sphere systems, LSRF-3 lamp start and flicker system and LS2090 LED driver tester.
The Pst versions add programmable voltage fluctuation to IEC TR 61547-1:2020, IEC 61000-3-3, IEC 61000-4-15 and IEEE 1453, and work with the LSRF-3 to measure the Pst LM(I) flicker immunity of lighting products.
| Specification | LSP-500VARC | LSP-500VARC-Pst | LSP-1KVARC | LSP-1KVARC-Pst |
|---|---|---|---|---|
| Output | Single phase, 2~150V / 2~300V | |||
| Max current (2~150V) | 4.2A | 4.2A | 8.4A | 8.4A |
| Max current (2~300V) | 2.1A | 2.1A | 4.2A | 4.2A |
| Frequency | 45.00~65.00Hz | |||
| Frequency stability | ≤0.05% / 30min | |||
| THD | ≤0.3% (no load or full resistive load) | |||
| Voltage stability | ≤0.1% / 30min | |||
| Load effect | ≤0.1% | |||
| Pst flicker programming | No | Yes | No | Yes |
| Meter ranges | Voltage 55V/220V, 0.1V resolution; current 0.2A/2A, 0.001A resolution; power 0.1W resolution | |||
| Meter accuracy | ±(0.4% rdg + 0.2% rng + 1 digit) for V, I and P | |||
| Interface | RS232 / RS485 | |||
IEC TR 61547-1 tests how much a lamp's light flickers when the supply voltage fluctuates. The Pst models generate the required voltage fluctuations, and with the LSRF-3 they measure Pst LM(I).
Choose by the load: the 500VA model gives 2.1A at up to 300V; the 1kVA model gives 4.2A.