LISUN LS5560/LS5562 battery testers measure internal resistance and voltage together: AC 4-terminal 1kHz, 0.1μΩ resolution, 100 readings/s, 60V or 300V.
Enquire About This Product
A cell's internal resistance and open-circuit voltage are the quickest indicators of its quality, and battery makers use them to grade and match cells. The LS5560 series measures both at the same time using the AC four-terminal method at 1kHz.
Resolution is 0.1μΩ and 10μV, with up to 100 readings per second for high-speed sorting lines. A contact check confirms the test leads are making contact, a 10-bin comparator and Handler interface drive automatic sorting, and RS232 (RS485 optional) supports SCPI and Modbus RTU. 50 setups are stored internally and 500 on a USB drive, and results can be uploaded to a PC without installing software. The LS5562A measures packs up to 300V DC.
| Specification | LS5560 | LS5562 | LS5562A |
|---|---|---|---|
| Parameters | Resistance and voltage (R, V, RV) | ||
| Method | AC four-terminal, 1kHz | ||
| Max input voltage | 60V DC | 60V DC | 300V DC |
| Resistance ranges | 5 ranges, 3mΩ~30Ω | 7 ranges, 3mΩ~3000Ω | |
| Best resolution | 0.1μΩ (3mΩ range) | ||
| Resistance accuracy | ±0.5% rdg ±5 digits (30mΩ~3000Ω); ±0.5% rdg ±10 digits (3mΩ~30mΩ) | ||
| Voltage ranges | 6V / 60V (10μV / 100μV) | 6V / 60V / 300V | |
| Speed | up to 100 readings per second | ||
| Sorting | 10-bin comparator, Handler interface | ||
| Interfaces | RS232 (RS485 optional), SCPI, Modbus RTU | ||
The AC four-terminal method measures internal resistance without discharging the cell and cancels the effect of lead resistance.
The LS5562A, which accepts up to 300V DC. The LS5560 and LS5562 are for cells and packs up to 60V.