LISUN LS-B74 UL 1598 test wall for temperature tests on wall-mounted luminaires: 1218mm plywood wall, octagonal outlet box, 14AWG wiring, on casters.
Enquire About This ProductWall-mounted luminaires are temperature tested on a standard test wall defined in UL 1598, so that temperatures at the mounting surface and in the outlet box reflect a real installation. Unlike the test ceiling, the test wall has no fibreglass insulation.
The LISUN LS-B74 is built to those requirements. Its front and back are 1218 × 1218mm, 12mm plywood on 2×4 inch side and internal timbers and 1×4 inch end timbers, with a UL-listed 4 × 1-1/2 inch octagonal outlet box, an external junction box on the side and 3/8 inch metal conduit inside. Wiring is one black and one white 14AWG conductor plus a 16AWG or heavier earth. The wall is mounted so its base is at least 0.9m above the floor, on a movable frame with casters. A branch circuit temperature probe to UL 1598 Figure 19.9.1 is part of the specification.
| Item | Specification |
|---|---|
| Overall size | 1220 × 700 × 2180mm (L × W × H) |
| Wall boards | 1218 × 1218mm, 12mm plywood, front and back |
| Timber | 2×4 in sides and internal supports; 1×4 in ends, horizontal |
| Insulation | None (as UL 1598 requires for the test wall) |
| Outlet box | Octagonal, 4 × 1-1/2 in, to UL 1598 Clause 19.10 |
| Conduit | 3/8 in metal, with external junction box on the side |
| Wiring | Black and white 14AWG, earth 16AWG or heavier |
| Branch circuit probe | To UL 1598 Clause 19.9 and Figure 19.9.1 |
| Mounting | Base at least 0.9m above floor, movable frame with casters |
The test wall has no fibreglass insulation, uses 2×4 inch timbers and is mounted vertically with its base at least 0.9m above the floor.