LISUN LFCI61000-16 common-mode conducted immunity system to IEC/EN 61000-4-16: DC to 150kHz, continuous, short-duration and sweep tests, built-in 3-phase CDN.
Enquire About This Product
Low-frequency common-mode disturbances reach equipment through leakage currents in power distribution systems, ground loops and noise on DC supply networks. IEC 61000-4-16 tests how well a product's power, signal and communication ports withstand them, from DC up to 150kHz.
The LFCI61000-16 puts the signal source, power amplifier and a three-phase coupling/decoupling network into one system. It runs all three test types in the standard: continuous disturbance at DC, 16⅔Hz, 50Hz and 60Hz (Table 1); short-duration disturbance up to 300V (Table 2); and a swept test from 15Hz to 150kHz (Table 3). It is controlled from a 10.1-inch English/Chinese touch screen or remotely from a PC.
Typical users are makers of electricity meters, industrial controls, relays, rail transit, communication and power electronic equipment, as well as third-party labs. LISUN recommends using it with an ITEU-TP10K or ITUS-TP5K isolation transformer (extra cost).
| Test | Continuous disturbance | Short-duration disturbance | Sweep test |
|---|---|---|---|
| Standard reference | IEC/EN 61000-4-16 Table 1 | IEC/EN 61000-4-16 Table 2 | IEC/EN 61000-4-16 Table 3 |
| Test frequency | DC, 16⅔Hz, 50Hz, 60Hz | 15Hz~150kHz | |
| Open-circuit voltage | 0.1~30V ±5% | 10~300V ±5% | 0.1~30V ±5% |
| Rise/fall time | – | 1~5μs | – |
| Output impedance | 50Ω ±10% | ||
| THD | <5% (sine) | ||
| EUT supply | Built-in three-phase CDN, AC 380V / 16A | ||
| Control | 10.1-inch Android touch screen (English/Chinese), PC remote software | ||
| Interfaces | LAN, USB, RS485 | ||
| Environment | 10~40℃, 30~70% RH | ||
| Supply | AC 110~250V / 10A, 50/60Hz | ||
The LFCI61000-16 applies common-mode disturbances (line to ground) from DC to 150kHz to IEC 61000-4-16. The LFCI61000-19 applies differential-mode disturbances on AC power ports from 2kHz to 150kHz to IEC 61000-4-19.
LISUN recommends the ITEU-TP10K or ITUS-TP5K isolation transformer with this system.