LISUN LFCI61000-16 common-mode conducted immunity system to IEC/EN 61000-4-16: DC to 150kHz, continuous, short-duration and sweep tests, built-in 3-phase CDN.

Conducted Immunity Test Systems
EMS Test System
Instrument System
IEC 61000-4-16:2015; EN 61000-4-16; IEC 60255-22-7:2003; EN 60255-22-7:2003; GB/T 17626.16-2007
Enquire About This Product
LISUN LFCI61000-16 Low Frequency Common-Mode Immunity

Overview

Low-frequency common-mode disturbances reach equipment through leakage currents in power distribution systems, ground loops and noise on DC supply networks. IEC 61000-4-16 tests how well a product's power, signal and communication ports withstand them, from DC up to 150kHz.

The LFCI61000-16 puts the signal source, power amplifier and a three-phase coupling/decoupling network into one system. It runs all three test types in the standard: continuous disturbance at DC, 16⅔Hz, 50Hz and 60Hz (Table 1); short-duration disturbance up to 300V (Table 2); and a swept test from 15Hz to 150kHz (Table 3). It is controlled from a 10.1-inch English/Chinese touch screen or remotely from a PC.

Typical users are makers of electricity meters, industrial controls, relays, rail transit, communication and power electronic equipment, as well as third-party labs. LISUN recommends using it with an ITEU-TP10K or ITUS-TP5K isolation transformer (extra cost).

Key Specifications

TestContinuous disturbanceShort-duration disturbanceSweep test
Standard referenceIEC/EN 61000-4-16 Table 1IEC/EN 61000-4-16 Table 2IEC/EN 61000-4-16 Table 3
Test frequencyDC, 16⅔Hz, 50Hz, 60Hz15Hz~150kHz
Open-circuit voltage0.1~30V ±5%10~300V ±5%0.1~30V ±5%
Rise/fall time–1~5μs–
Output impedance50Ω ±10%
THD<5% (sine)
EUT supplyBuilt-in three-phase CDN, AC 380V / 16A
Control10.1-inch Android touch screen (English/Chinese), PC remote software
InterfacesLAN, USB, RS485
Environment10~40℃, 30~70% RH
SupplyAC 110~250V / 10A, 50/60Hz

Features

Applications

Frequently asked questions

What is the difference between this and the LFCI61000-19?

The LFCI61000-16 applies common-mode disturbances (line to ground) from DC to 150kHz to IEC 61000-4-16. The LFCI61000-19 applies differential-mode disturbances on AC power ports from 2kHz to 150kHz to IEC 61000-4-19.

Do I need an isolation transformer?

LISUN recommends the ITEU-TP10K or ITUS-TP5K isolation transformer with this system.