LISUN LS-ISO16750 system for ISO 16750-2:2023, VW 80000, LV 124 and GM 3172: supply variation, load dump, micro-interruptions and ground offset.
Enquire About This Product
ISO 16750-2 sets the electrical stresses that automotive electronic components must survive: supply voltage variations, transient overvoltage, superimposed AC ripple, slow voltage changes, drops and interruptions, reverse polarity, starting profiles, load dump, ground offsets and harness interruptions. Carmakers add their own versions in VW 80000, LV 124, GM 3172 and Nissan 28401.
The LS-ISO16750 brings LISUN's dedicated instruments together in one 19-inch cabinet to cover 12 core test items of ISO 16750-2:2023 and the matching OEM tests. It is used for R&D verification, production quality checks and third-party certification of ECUs, sensors and on-board chargers.
| ISO 16750-2:2023 test | VW 80000 equivalent | LISUN instrument |
|---|---|---|
| 4.2 DC supply voltage | Chapter 5 general requirements | LIS-APS-4030K300 |
| 4.3.1 Overvoltage | E-01 long-term overvoltage | LIS-APS-4030K300 |
| 4.3.2 Transient overvoltage | E-02 transient overvoltage | LIS-APS-4030K300 |
| 4.4 Superimposed alternating voltage | E-06 ripple voltage | LIS-APS-4030K300 |
| 4.5 Slow decrease and increase of supply voltage | E-07 slow rise and fall | LIS-APS-4030K300 |
| 4.6.1 Drops or interruptions in supply voltage | E-03 and E-10 | LIS-APS-4030K300 |
| 4.6.2 Reset behaviour at voltage drop | E-09 reset behaviour | LIS-APS-4030K300 |
| 4.6.3 Starting profile | E-11 starting pulse | LIS-APS-4030K300 |
| 4.7 Reversed voltage | E-15 reverse polarity | LIS-APS-4030K300 |
| 4.6.4 Load dump | – | EMS-ISO7637-P5-80V30A |
| 4.8 Ground reference and supply offset | – | LIS-OFFSET-D10A |
| 4.9 Discontinuities in supply voltage | – | PFS-80V50A |
| 4.10 Open and short circuit | – | LIS-LSCS-1730 |
The load dump pulses are included. For pulses 1, 2a and 3a/3b, add LISUN's EMS-ISO7637 generator.
Yes. Each instrument in the cabinet is also sold on its own: the LIS-APS, PFS, LIS-OFFSET-D and LIS-LSCS series.