LISUN
Home
/
Photometric Measurement Systems

IS-*MT Constant Temperature Integrating Sphere – LISUN

IS-1.0MT / IS-1.5MT / IS-1.75MT / IS-2.0MT

LISUN IS-*MT constant temperature integrating sphere holds 25°C (to 55°C) for high-power LED and HID testing to IES LM-82 Clause 4.4. 1.0m to 2.0m.

Photometric Measurement Systems
Integrating Sphere
Sphere System (floor-standing, temperature controlled)
IES LM-82 Clause 4.4; CIE 84:1989; IEC (25°C test temperature)
Enquire About This Product
LISUN IS-*MT Constant Temperature Integrating Sphere

Overview

IEC standards specify a 25°C test temperature, but high-power HID lamps and outdoor LED luminaires heat the inside of a normal integrating sphere well above that during a test. LISUN's IS-*MT constant temperature sphere (also called a thermostatic or temperature-controlled sphere) holds the internal temperature at 25°C, and can also be set higher, up to 55°C, for temperature-dependence testing to IES LM-82 Clause 4.4.

Apart from the temperature control, it has the same construction as LISUN's IS-*MA spheres: BaSO4 coating to CIE 84, lamp jigs for E27 and T5/T8/T12, a holder base for LED luminaires, built-in power connections, detector, fibre and temperature ports, and a cross laser for centring on spheres over 1m. It is the optional sphere in the LPCE-2 system's LM-82 kit, used with a TMP-8 or TMP-16 multiplex temperature tester.

Key Specifications

Specifications

SpecificationIS-*MT series
DiametersIS-1.0MT, IS-1.5MT (1.5m), IS-1.75MT (1.75m), IS-2.0MT (2.0m); larger to order
Temperature control25°C to 55°C (25°C reference); rise tolerance ±1°C, drop tolerance ±2°C
CoatingBaSO4 to CIE Pub. No. 84 (1989)
Spectral reflectanceρ(λ) ≥0.96 (450~800nm); ρ(λ) ≥0.92 (380~450nm)
Diffuse reflectanceρ≈0.8, accuracy of ρ(λ) <1.5%
Sample mountingE27, T5/T8/T12 jigs and LED luminaire holder base; up or down orientation
Built-inPower cable and socket, auxiliary lamp position, 2 detector ports, 1 fibre port, 1 temperature sensor port
AlignmentCross laser (spheres larger than 1m)

Flux range by size

ModelTypical samplesLuminous flux range
IS-1.0MTCFL and LED bulbs0.1~199,990 lm
IS-1.5MT / IS-1.75MTCFL, LED bulbs and tubes, fluorescent lamps, CCFL0.1~1,999,900 lm
IS-2.0MTHID and high-power lamps0.1~1,999,900 lm

Features

Applications

Frequently asked questions

Why does sphere temperature matter?

LED and HID light output changes with temperature. IEC test methods specify 25°C, so a sphere that heats up during the test gives readings that are not comparable. The IS-*MT keeps the temperature controlled.

What is IES LM-82?

The IES method for characterising LED light engines and lamps as a function of temperature. LISUN states the IS-*MT meets LM-82 Clause 4.4.