LISUN LS-B59 high frequency spark generator to IEC 61347-1:2024 Clause 11.4.2, to check whether gases escaping from faulty ballasts and controlgear ignite.
Enquire About This Product
When lamp controlgear such as a ballast fails, components like capacitors can vent gases. IEC 61347-1 Clause 11.4.2 checks whether those gases are flammable by bringing a high-frequency spark near the point where they escape during the fault test.
The LS-B59 generates that spark. It has an insulated handle so the operator can hold the spark tip close to the sample safely, push-button control, and a compact painted steel housing. It is used by ballast and controlgear manufacturers before shipment, by certification labs, in R&D fault testing, in procurement and incoming quality checks, and by market surveillance bodies for spot checks.
| Item | Specification |
|---|---|
| Supply | AC 220~240V, 50/60Hz, 20W max |
| Control | Push button |
| Housing | Painted steel |
| Dimensions | 200 × 140 × 120mm (excluding handle) |
During the controlgear fault tests, to check whether gas escaping from the sample can be ignited.