LISUN JL-UL50EC86 hosedown tester for UL 50E 8.4.1.2/8.6, CSA C22.2 No. 94.2 and NMX-J-235/2: 25mm nozzle, 170 and 240 L/min, 1000L tank, turntable.
Enquire About This Product
The LISUN JL-UL50EC86 carries out the hosedown (water jet) test for electrical equipment enclosures in UL 50E Clauses 8.4.1.2 and 8.6, CSA C22.2 No. 94.2:20 and NMX-J-235/2-ANCE-2020. It simulates high-pressure water jets outdoors and in wash-down areas, and is used for luminaires, appliances, automotive parts and electrical control enclosures, from R&D through to factory inspection and UL certification testing.
The cabinet and sample turntable are SUS304 stainless steel. A 1000-litre tank refills automatically through a float valve, and a low-level alarm protects the pump from running dry. The turntable is driven by a speed-controlled motor that can reverse, so a powered sample can be tested without its cable winding up, and the turntable's electrical parts are fully sealed.
Water flow is set manually and read on a rotor flow meter, with a 25mm nozzle made to UL 50E. The nozzle is held 2.5–3m from the sample on a fixed bracket, so nobody has to hold the hose during long tests. A 220V/10A socket on the turntable powers the sample, with programmable on/off cycles of 0–999 minutes. Test time is set on a 7-inch touchscreen and the machine stops automatically at the end.
| Parameter | Value |
|---|---|
| Overall dimensions | 1450 × 900 × 1300mm (on casters) |
| Turntable | Ø600mm, max. load 50kg, fixed height |
| Water tank | 1000 L |
| Nozzle diameter | 25mm |
| Spray distance | 2.5–3m, fixed nozzle bracket |
| Flow rate | 170 L/min and 240 L/min ±5%, manually adjusted |
| Water use | Single pass, not recirculated |
| Sample power | AC 220V / 10A |
| Control | 7-inch touchscreen, Panasonic PLC |
| Supply | Three-phase AC 380V, 4.0kW |
| Protection | Earth leakage, low water level, short circuit |
The apparatus provides 170 L/min and 240 L/min (±5%), set on the flow meter, to cover the hosedown conditions in UL 50E and the matching CSA and NMX standards.
No. Each test uses a single pass of fresh water from the tank.