LISUN LAP combined temperature and altitude chambers, 100L to 2000L: down to −70°C, up to 150°C, pressure to 0.5kPa, for IEC 60068-2-40/41 and MIL-STD-810H.
Enquire About This Product
The LISUN LAP series simulates the combination of low air pressure and extreme temperature found at high altitude and in aircraft. Each chamber can run low temperature, high temperature and low pressure singly or together, for the combined cold and low pressure test of IEC 60068-2-40 (Test Z/AM), the combined dry heat and low pressure test of IEC 60068-2-41 (Test Z/BM), package altitude tests to ASTM D6653 and ISO 2873, and the low pressure (altitude) method of MIL-STD-810H.
Refrigeration uses hermetic TECUMSEH compressors, single-stage or cascade depending on the low-temperature range, and heating is by independent nichrome heaters. Pressure is measured by an electronic pressure transmitter and controlled by a vacuum system that brings the chamber from atmospheric pressure to 0.5kPa in 60 minutes or less. The chambers are controlled from a colour LCD touchscreen and protected against leakage, short circuit, over-temperature, motor overheating, compressor over-pressure, overload and over-current.
| Model | LAP-100 | LAP-250 | LAP-500 | LAP-010 | LAP-015 | LAP-020 |
|---|---|---|---|---|---|---|
| Working space (cm) | 41 × 55 × 45 | 50 × 60 × 75 | 70 × 80 × 90 | 100 × 100 × 100 | 100 × 100 × 150 | 100 × 100 × 200 |
| Power | 5.5kW | 8.0kW | 9.0kW | 11.0kW | 17.0kW | 22.0kW |
| Temperature range | A: −20 to 150°C; B: −40 to 150°C; C: −60 to 150°C; D: −70 to 150°C | |||||
| Temperature fluctuation / uniformity / deviation | ±0.5°C / ±2°C / ±3°C (atmospheric pressure, no load) | |||||
| Heating / cooling rate | 1.0–3.0°C/min / 0.7–1.0°C/min (no load) | |||||
| Pressure range | Atmospheric to 0.5kPa | |||||
| Pressure deviation | ±1.8kPa (atmospheric to 40kPa); ±4.5% (40 to 4kPa); ±0.1kPa (4 to 0.5kPa) | |||||
| Pump-down time | ≤60min, atmospheric to 0.5kPa | |||||
| Sensors | Pt100 temperature sensor; electronic pressure transmitter | |||||
| Interior / exterior | SUS304 stainless steel / coated carbon steel or SUS304 | |||||
| Power supply | 3-phase 5-wire AC 380V, 50Hz (60Hz optional) | |||||
Add the temperature range letter to the model, for example LAP-100B for −40 to 150°C. Special sizes and ranges can be built to order.
Pick the letter that covers your coldest test: A to −20°C, B to −40°C, C to −60°C or D to −70°C. All go to +150°C.
The chamber pumps down from atmospheric pressure to 0.5kPa in 60 minutes or less.