LISUN haze meters measure haze and total transmittance to ASTM D1003 and ISO 13468/14782; the HM-700 adds spectral transmittance and liquid colour indices.
Enquire About This Product
Haze and luminous transmittance decide how clear a film, sheet, lens or display cover looks. LISUN's haze meters measure both to ASTM D1003 and, on the HM-120 and HM-700, to ISO 13468 and ISO 14782 as well, using 0/d transmission geometry with an integrating sphere. The open sample area has no size limit, and samples can be measured horizontally or vertically.
The HM-120 needs no warm-up and gives a result in 1.5 seconds. It measures under CIE-A, CIE-C and CIE-D65 sources with 21mm and 7mm apertures, a 7-inch Android touch screen and 0.05% transmittance repeatability. The HM-100 is the simpler model: ASTM haze only, CIE-A and CIE-C sources, one 21mm aperture and a 5-inch screen.
The HM-700 combines haze measurement with a 400–700nm spectrophotometer, so the same instrument reports spectral transmittance and dozens of colour indices including Lab, yellowness and whiteness, Gardner and Pt-Co/APHA/Hazen. It offers 24 illuminants for colour work, transmittance compensation, measuring fixtures for sheet and liquid samples, and Color QC software for reports on a PC.
| Specification | HM-100 | HM-120 |
|---|---|---|
| Light source | CIE-A, CIE-C | CIE-A, CIE-C, CIE-D65 |
| Standards | ASTM D1003/D1044, JIS K7105, JIS K7361, JIS K7136, GB/T 2410-08 | ASTM D1003/D1044, ISO 13468/14782, JIS K7105, JIS K7361, JIS K7136, GB/T 2410-08 |
| Test parameters | ASTM haze, transmittance (T) | ASTM and ISO haze, transmittance (T) |
| Test aperture | 21mm | 21mm, 7mm |
| Screen | 5-inch TFT LCD | 7-inch touch screen, Android |
| Measuring range | 0~100% | |
| Transmittance repeatability | ≤0.1% | ≤0.05% |
| Haze / transmittance resolution | 0.01% | |
| Optical path | Transmission 0/d (parallel illumination, diffuse reception) | |
| Integrating sphere | Φ154mm | |
| Light source type | 400~700nm full-spectrum LED | |
| Sample size | Open space, no size limit | |
| Data storage | 10,000 values | Mass storage |
| Interface / power | USB; DC12V/3A | |
| Operating environment | 5~40℃, ≤80% RH at 35℃, non-condensing | |
| Size | 310×215×540mm | |
| Specification | HM-700 |
|---|---|
| Light source | Haze/transmittance: CIE-A, CIE-C, CIE-D65; colour: A, C, D50, D55, D65, D75, F1–F12, CWF, U30, DLF, NBF, TL83, TL84 |
| Parameters | Haze, transmittance, spectral transmittance, CIE Lab, LCh, Luv, XYZ, Yxy, Hunter Lab, Munsell, CMYK, whiteness and yellowness indices, tint, metamerism index, APHA/Pt-Co, Gardner, colour difference (ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00) |
| Measuring range | 0~100% (haze, transmittance) |
| Wavelength range / interval | 400~700nm / 10nm |
| Geometry | 0/d |
| Illumination area / aperture | 16.5mm / 21mm |
| Resolution | 0.01 unit |
| Repeatability | Haze <10%: ≤0.05; haze ≥10%: ≤0.1%; transmittance ≤0.1% |
| Sample size | Thickness ≤145mm |
| Display / storage | 7-inch touch screen; 20,000 values |
| Interface / power | USB; 110V/220V/240V |
| Operating environment | 0~45℃, ≤80% RH at 35℃, non-condensing |
| Size | 598×247×366mm (L×W×H) |
| Included / optional | PC software (Color QC); optional measuring fixture, haze standard sheet, 5/7/10mm aperture plates, 40×10 cuvette |
The two standard families define the haze measurement differently. The HM-100 measures to ASTM only; the HM-120 and HM-700 measure to both ASTM (D1003) and ISO (13468/14782).
The HM-700 can: it reports liquid colour scales such as Gardner and Pt-Co/APHA/Hazen, and LISUN offers a 40×10 cuvette and fixtures for liquid samples. The HM-120 is intended for sheet, film, glass and screen samples.
The measurement area is open, so sample width and height are not limited. The HM-700 accepts samples up to 145mm thick.