LISUN
Home
/
EMC & EMI Test Equipment

GTEM Cell for Radiated Immunity and Emission Tests – LISUN

GTEM-2 / GTEM-4 / GTEM-6 / GTEM-8

LISUN GTEM cells, DC to 6GHz, for radiated immunity (IEC 61000-4-3, 61000-4-20) and emission tests. Four sizes for EUTs from 120mm to 600mm.

EMC & EMI Test Equipment
EMI Test System
Test Chamber
IEC 61000-4-3; IEC 61000-4-20; CISPR 11; CISPR 14; CISPR 20; CISPR 22; CISPR 25; GB/T 17626.3; GB/T 17215
Enquire About This Product
GTEM Cell for Radiated Immunity and Emission Tests

Overview

A GTEM (gigahertz transverse electromagnetic) cell is a tapered, shielded transmission line that produces a uniform electromagnetic field inside a compact enclosure. It is a lower-cost, faster alternative to an anechoic chamber or open-area test site for testing small products.

Because a GTEM cell works from DC into the microwave range, the same cell can be used for radiated immunity (EMS) testing, by feeding it from a signal generator and power amplifier, and for radiated emission (EMI) testing, by connecting it to an EMI receiver. LISUN makes four sizes. The GTEM-2 and GTEM-4 ship assembled in a 40HQ container; the GTEM-6 and GTEM-8 are assembled on site.

Complete systems

For radiated immunity, LISUN supplies the GTEM-EMS system: GTEM cell, signal generator, power meter, field probe and power amplifier, covering IEC 61000-4-3 levels 1 (1V/m) to 4 (30V/m).

Key Specifications

SpecificationGTEM-2GTEM-4GTEM-6GTEM-8
Calibrated field strengthExternal modulation 30V/m, internal modulation 50V/m
Frequency rangeDC~6GHz (depends on amplifier or receiver)
Impedance50Ω
VSWR≤1.5 typical
Max input power200W1000W1100W1500W
Septum height350mm750mm1100mm1900mm
Max EUT size240×240×240mm585×500×500mm800×800×800mm1200×1000×1000mm
Max EUT in 6dB uniform field120×120×120mm250×250×250mm350×350×350mm600×600×600mm
Door size (W×H)250×300mm750×750mm900×900mm1300×1000mm
External size (L×W×H)1950×950×700mm4150×2150×1450mm6200×3100×2100mm8000×4050×2850mm
Power filterSingle phase 16ASingle phase 16A and three phase 32A
Weight with standabout 260kgabout 950kgabout 1380kgabout 1800kg

Features

Applications

Frequently asked questions

Which size do I need?

Size by the 6dB uniform field area: the EUT must fit inside it. That is 120mm for the GTEM-2 and up to 600mm for the GTEM-8.

Can a GTEM cell replace an anechoic chamber?

For small products, IEC 61000-4-20 sets out how TEM waveguides such as GTEM cells can be used for emission and immunity tests. Larger products still need a chamber.

Related Reading