LISUN LS-UL2556F17 glancing impact tester for cable jackets and insulation to UL 2556:2021 Clause 7.14.2 and Figure 17: 0.454kg hammer, 45° specimen block.
Enquire About This ProductThe LISUN LS-UL2556F17 performs the glancing impact test of UL 2556:2021 Clause 7.14.2, built to the dimensions of Figure 17. It checks how well a cable's jacket and insulation stand up to a hard object striking it at an angle, as can happen when cable is pulled and laid during installation.
The apparatus is made for North American cable certification to UL 2556 and CSA C22.2 No. 2556:2021.
The cable sample lies on a wooden block set at 45°. A 0.454kg hammer with a rounded R9.5mm head is released from a fixed height inside a vertical guide tube and strikes the sample at an angle. The hammer is released by a pin and falls under gravity alone, so the impact energy is the same every time. The sample is then checked for damage to the jacket and insulation as the standard requires.
The frame is thick carbon steel on a heavy cast-iron base, so the hammer does not drift off line. The hammer mass, guide tube height and 45° support all follow Figure 17.
| Parameter | Value |
|---|---|
| Hammer total mass | 0.454kg, +0.009 / 0kg |
| Impact column diameter | 19mm, 0 / −1.00mm |
| Impact head radius | R9.5mm, 0 / −0.5mm |
| Guide tube inner diameter | 21mm, +0.5 / 0mm |
| Guide tube length | 1390mm |
| Bottom impact plate | 101.6 × 101.6mm, 25.4mm thick |
| Specimen support | Wooden block at 45° |
In a glancing impact test the cable lies at 45° to the falling hammer, so the blow is oblique, like a cable scraped by a hard edge during installation, rather than a square-on crush.
Yes. CSA C22.2 No. 2556:2021 is harmonised with UL 2556, so the same apparatus is used.