LISUN ETUS step-up transformers convert 110V single phase or 240V three phase mains to 220V or 380V to run test equipment: 2kVA to 80kVA.
Enquire About This Product
Much test equipment is built for 220V single phase or 380V three phase supplies. The ETUS series converts 110–120V single phase or 220–240V three phase mains, as found in the USA and Japan, up to 220V single phase or 380V three phase so that equipment can be run directly.
Output voltage stability follows the stability of the input. For a clean, stable and isolated supply, the ETUS can be used together with the ITEU-SP4K isolation transformer. Because step-up transformer efficiency is about 55–60%, choose a model with at least twice the power your equipment needs: a 10kW load needs at least the ETUS-TP20K.
| Model | Input | Output | Power |
|---|---|---|---|
| ETUS-SP2K | Single phase L/N, 110V (100V or other optional) | Single phase L/N/PE, 220V | 2kVA |
| ETUS-SP5K | Single phase L/N, 110V (100V or other optional) | Single phase L/N/PE, 220V | 5kVA |
| ETUS-TP10K | Three phase A/B/C, 240V line to line (other optional) | Three phase L1/L2/L3/N/PE, 380V | 10kVA |
| ETUS-TP20K | Three phase A/B/C, 240V line to line | Three phase L1/L2/L3/N/PE, 380V | 20kVA |
| ETUS-TP30K | Three phase A/B/C, 240V line to line | Three phase L1/L2/L3/N/PE, 380V | 30kVA |
| ETUS-TP40K | Three phase A/B/C, 240V line to line | Three phase L1/L2/L3/N/PE, 380V | 40kVA |
| ETUS-TP60K | Three phase A/B/C, 240V line to line | Three phase L1/L2/L3/N/PE, 380V | 60kVA |
| ETUS-TP80K | Three phase A/B/C, 240V line to line | Three phase L1/L2/L3/N/PE, 380V | 80kVA |
Efficiency is about 55–60%, so allow at least twice your load: a 10kW load needs at least the ETUS-TP20K.
Usually not. Australian mains is 230V single phase and 400V three phase, which suits 220V/380V equipment directly. The ETUS is for 110V and 240V three-phase regions.