LISUN
Home
/
EMC & EMI Test Equipment

EMI-9K EMI Test Receiver System (CISPR 16-1-1) – LISUN

EMI-9KC / EMI-9KBS / EMI-9KB / EMI-9KA

LISUN EMI-9K EMI receiver systems to CISPR 16-1-1: conducted and radiated emissions from 9kHz to 1GHz, PK/QP/AV detectors, LISN and PC software included.

EMC & EMI Test Equipment
EMI Receiver / Conducted & Radiated EMI Test
Instrument System
CISPR 16-1-1:2019; CISPR 32:2019; CISPR 22:2006; CISPR 14-1:2021; CISPR 15:2018; EN 55022:2015; EN 55014-1:2021; EN 55015:2019; IEC 61000-6-3:2020; GB/T 6113.101-2021; GB/T 9254.1-2021; GB 4343.1-2018; GB 17743-2022
Enquire About This Product
EMI-9K EMI Test Receiver System (CISPR 16-1-1)

Overview

The EMI-9K series measures the electromagnetic interference a product gives off while it runs: conducted interference that travels back along its power and signal leads, and radiated interference that travels through the air. It is used to check products against emission limits before EMC certification and to track down noise sources such as switching power supplies and motors.

The receiver uses a fully enclosed, shielded design to avoid self-interference, and offers peak, quasi-peak and average detectors with the CISPR bandwidths of 200Hz, 9kHz and 120kHz. Each system ships with the receiver, a LISN, an isolation transformer and coaxial cable; the EMI-9KC adds a CDNE for the 30–300MHz CISPR 15 method. Results are handled in English PC software for Windows 7 to 11, and the top models also have a built-in touch screen.

Typical users are manufacturers, R&D centres and test labs working on LED lighting, switching power supplies, power tools, household appliances and IT equipment.

Optional accessories

Key Specifications

SpecificationEMI-9KCEMI-9KBSEMI-9KBEMI-9KA
Frequency range9kHz~1000MHz9kHz~300MHz9kHz~300MHz9kHz~30MHz
System configurationEMI receiver, LISN, CDNE, isolation transformer, coaxial cableEMI receiver, LISN, isolation transformer, coaxial cable
Frequency resolutionMin 1Hz
Frequency stability1×10⁻⁷1×10⁻⁶
Input impedance50Ω
Input attenuationInternal 30dB (0/10/20/30dB)External 20dB (0/10/20dB)
Input VSWR≤2 (RF ATT 0dB); ≤1.2 (RF ATT 10dB)
DetectorsPeak, quasi-peak, average
Noise floor (peak)0dBμV (9kHz~30MHz); ≤10dBμV (30MHz~1000MHz)
Measurement range0~120dBμV (CW)
Pulse characteristicsMeet CISPR 16-1-1 and GB/T 6113.101
Basic accuracy±1dB±1.8dB
PreselectionTwo-stage 20-channel fixed preselector (9kHz~30MHz) and tracking preselector (30MHz~1GHz)None
IF rejection≥85dB
Test bandwidth (-6dB)200Hz (9kHz~150kHz); 9kHz (150kHz~30MHz); 120kHz (30MHz~1GHz)
OperationManual and automaticAutomatic
DisplayBuilt-in LCD touch screen plus PC softwarePC software (Windows 7/8/10/11)
Supply100~240VAC, 50/60Hz200~240VAC, 50/60Hz

Features

Applications

Frequently asked questions

Which model do I need?

Choose by frequency range. The EMI-9KA covers conducted emissions to 30MHz; the EMI-9KB and EMI-9KBS go to 300MHz; the EMI-9KC goes to 1GHz and includes a CDNE and preselection.

Can it measure radiated emissions without a chamber?

For lighting, CISPR 15 allows the CDNE method (30–300MHz) and the triple loop antenna method (9kHz–30MHz), which the EMI-9KC and the optional VVLA-30M support. Other products may need a chamber or open-area test site.

Related Reading