LISUN HF2686C electrolytic capacitor tester: 0–200V or 0–500V test voltage, leakage current 0.1μA to 30mA, 200mA charge current, ±2% accuracy.
Enquire About This Product
An electrolytic capacitor always passes a small leakage current when it is charged, and a high or rising leakage current is an early sign of a weak or failing part. The leakage test charges the capacitor to its rated voltage for a set time and then measures the current that still flows.
The LISUN HF2686C applies a test voltage of 0–200V or 0–500V, with a maximum charging current of 200mA so capacitors reach voltage quickly, and selectable charge times from 0.5 seconds to 60 seconds. It measures leakage current from 0.1μA to 30mA with ±2% accuracy. It suits incoming inspection, production checks and failure analysis of aluminium electrolytic capacitors, including those used in lamp control gear and power supplies.
| Item | Specification |
|---|---|
| Test voltage | 0~200V / 0~500V |
| Leakage current range | 0.1μA~30mA |
| Maximum charge current | 200mA ±10% |
| Charge time | 0.5, 1, 2, 3, 4, 5, 7, 10, 30, 60s |
| Accuracy | ±2% |
Use the charge time in the capacitor's specification or your test standard; the HF2686C offers settings from 0.5s to 60s.
For insulation resistance as well as leakage current, see LISUN's LS6586 capacitor leakage current tester.