LISUN common mode inductor balance testers measure Ls and DCR balance of chokes: 1 to 3 winding pairs, up to 200kHz, accuracy to 0.05%, Handler interface.
Enquire About This Product
A common mode choke only filters well if its windings are closely matched. Balance testers, also called filter balance testers, measure the inductance (Ls) and DC resistance (DCR) of each winding and the balance between them.
The LS8517CX range covers single-pair chokes (LS7575BN, LS1085CX) and multi-winding parts with two pairs (LS8517CX-4PA) or three pairs (LS8517CX-6PA). Accuracy is up to 0.05% on the higher models, for production line QC, incoming inspection and component design. Comprehensive communication and control interfaces simplify connection to automated equipment.
| Specification | LS7575BN | LS1085CX | LS8517CX-4PA | LS8517CX-6PA |
|---|---|---|---|---|
| Test frequency | 100Hz, 120Hz, 1kHz, 10kHz | 50Hz~200kHz, 42 points | 50Hz~200kHz, 37 points | |
| Winding pairs | 1 | 2 | 3 | |
| Parameters | L, Q, R | L, C, R, Q, Z, DCR | L, R, Q, Z, θ, C, DCR | |
| Test level | 0.1, 0.3, 1Vrms | 10mV~1Vrms | 50mV~2.0V | |
| Basic accuracy | 0.1% | 0.05% | ||
| L display range | 0.0001μH~999.99H | 0.0001μH~9999.9H | 0.0001μH~9999.9H | |
| Speed | 30 / 6 / 1.5 per second | 50 / 20 / 6 per second | ||
| Comparator | BIN0~BIN3, NG, Pass, Fail, buzzer | |||
| Interfaces | RS232C, USB host, USB device, Handler | |||
| Size | 310×110×315mm | |||
If the windings are not matched, the flux from the normal (differential) current does not fully cancel in the core, so the core can saturate and the choke filters common mode noise less effectively.
Choose by the number of winding pairs: one (LS7575BN, LS1085CX), two (LS8517CX-4PA) or three (LS8517CX-6PA).