LISUN
Home
/
Material & Optical Analysis

HSCD and DSCD Spectrophotometers – LISUN

HSCD-860 / DSCD-950P / DSCD-930S

LISUN spectrophotometers: HSCD-860 portable (dE*ab≤0.02), DSCD-950P benchtop reflectance/transmittance, DSCD-930S liquid colour (Pt-Co, Gardner, Saybolt).

Material & Optical Analysis
Object Color & Glossiness Test
Portable and Bench-top Instruments
CIE No.15; ISO 7724-1; ASTM E1164; DIN 5033-7; JIS Z8722; ASTM D1003; ASTM E313; ASTM D1925; ASTM D156; ASTM D1500; ASTM D1209; ASTM D5386; ASTM D6045; ASTM D6166; GB/T 3978; GB 2893; GB/T 18833
Enquire About This Product
LISUN HSCD and DSCD Spectrophotometers

Overview

These three LISUN spectrophotometers cover the main colour measurement jobs in a quality lab: a portable instrument for solid samples on the line, a benchtop instrument for both opaque and transparent materials, and a dedicated liquid colour instrument for chemicals, oils and pharmaceuticals. All three measure full spectral data in 10nm steps and calculate colour, colour difference and industry indices from it.

HSCD-860 portable spectrophotometer

The HSCD-860 is the high-precision model in LISUN's HSCD portable range. A dual-beam optical design measures the sample and monitors the light source at the same time, giving repeatability of dE*ab≤0.02 and inter-instrument agreement of dE*ab≤0.2. It measures in d/8 geometry with SCI and SCE, has an LED plus UV light source, six apertures (11mm, 6mm and 3mm in stable and agile types), a camera for sample positioning, and a zirconia white calibration tile that resists scratching and does not drift with temperature or humidity.

DSCD-950P benchtop spectrophotometer

The DSCD-950P measures reflectance in d/8 geometry (SCI and SCE, simultaneously in under 4 seconds) and transmittance in d/0 geometry, from 360nm to 780nm with a pulsed xenon lamp and LED, a 152mm integrating sphere and concave grating. Four UV modes handle fluorescent materials, the transmittance area takes samples of any width up to 50mm thick, and a 7-inch rotatable Android touch screen runs it. It also reports haze, liquid colour scales and paper brightness (R457).

DSCD-930S liquid spectrophotometer

The DSCD-930S measures liquid colour in transmission (d/0) over 360–780nm with more than 30 colour indices, including Pt-Co/APHA/Hazen, Gardner, Saybolt, ASTM colour and Chinese, US and European pharmacopoeia scales. It needs as little as 1ml of sample, uses 10mm and 50mm cuvettes as standard, measures in 1.5 seconds and keeps an audit trail. The DSCD-930H version adds a heated sample tank (ambient to 90°C) for fats, waxes and other samples that solidify.

Key Specifications

HSCD-860 (portable)

SpecificationHSCD-860
Measurement geometryd/8, SCI + SCE
RepeatabilitydE*ab≤0.02
Inter-instrument agreementdE*ab≤0.2
Apertures6 apertures: Φ11mm, Φ6mm, Φ3mm (stable and agile types)
Light sourceLED + UV
Sample viewingCamera
Integrating sphere40mm
Spectral method / sensorNano-integrated optical devices; dual 16-element silicon photodiode array
Wavelength range / interval400~700nm / 10nm
Reflectance range / resolution0~200% / 0.0001
Observer2°, 10°
MeasurementSingle or average (2–99 times); about 1 second
Screen3.5-inch full-colour touch screen
InterfaceUSB, Bluetooth
Battery8,000 measurements per charge, 3.7V/3,000mAh
Light source life1 million measurements in 10 years
Storage10,000 results on the instrument; mass storage in the app

DSCD-950P (benchtop, reflectance and transmittance)

SpecificationDSCD-950P
GeometryReflectance d/8, SCI/SCE simultaneous; transmittance d/0
Sensor / gratingSilicon photodiode array; concave grating
Integrating sphere152mm
Wavelength range / pitch360~780nm / 10nm; half band width 5nm
Reflectance range / resolution0~200% / 0.01%
Light sourcePulsed xenon lamp and LED
UV measurementUV included; 400nm, 420nm, 460nm cut-off
Measurement timeSCI or SCE <2s; SCI+SCE <4s
Reflectance aperturesXLAV Φ25.4/30mm; LAV Φ15/18mm; MAV Φ8/11mm; SAV Φ3/6mm (auto-recognised)
Transmittance aperture / sampleΦ17mm/Φ25mm; any width and height, thickness ≤50mm
RepeatabilitySpectral reflectance/transmittance SD within 0.1%; ΔE*ab SD within 0.015 (XLAV)
Inter-instrument agreementΔE*ab 0.15 (XLAV, BCRA Series II, 12 tiles, 23℃)
Illuminants / observerA, C, D50, D55, D65, D75, F1–F12, CWF, U30, DLF, NBF, TL83, TL84; 2° and 10°
IndicesWI, YI, tint, metamerism, stain and colour fastness, ISO brightness R457, A/T/E/M density, APHA/Pt-Co/Hazen, Gardner, Saybolt, ASTM colour, haze, total transmittance, opacity, colour strength
Screen / storage7-inch touch screen; 8GB USB storage
Interface / powerUSB, USB-B, RS-232; 12V/3A
Size / weight465×240×260mm; 10.8kg

DSCD-930S / DSCD-930H (liquids)

SpecificationDSCD-930SDSCD-930H
Geometryd/0 transmission
Integrating sphereΦ40mm
Light sourceFull-band balanced LED
Wavelength range / interval360~780nm / 10nm; half band width 5nm
Measuring range / resolution0~200% / 0.0001
Repeatability (colour)ΔE*ab≤0.015 (SD), max ≤0.04ΔE*ab≤0.01 (SD), max ≤0.03
Repeatability (transmittance)SD ≤0.08%SD ≤0.08%
Inter-instrument agreementΔE*ab <0.25ΔE*ab <0.2
HeatingNoneAmbient to 90℃
Measuring time≤1.5s
Cuvettes10mm and 50mm glass standard; 33mm and 100mm optional
IndicesPharmacopoeia colour (Chinese, European, US), WI, YI, tint, APHA, Hazen, Pt-Co, Gardner, iron-cobalt, Saybolt, ASTM colour, EBC (beer), ICUMSA (sugar)
Audit trailYes
Screen / storage7-inch touch screen; over 100,000 results
SoftwareColorExpert, Color QC2

Features

Applications

Frequently asked questions

What is the difference between SCI and SCE?

SCI includes the specular (gloss) reflection, so it measures the colour of the material itself. SCE excludes it, so it measures colour as the eye sees it, including the effect of surface finish. The HSCD-860 and DSCD-950P measure both.

Which model should I use for liquids?

The DSCD-930S (or the heated DSCD-930H). It measures in transmission with cuvettes and reports liquid colour scales such as Pt-Co, Gardner and Saybolt. The DSCD-950P can also measure liquids in transmission.

Can these instruments measure fluorescent samples?

The DSCD-950P has four UV test modes (UV included, 400nm, 420nm and 460nm cut-offs) for fluorescent materials, and the HSCD-860 has an LED plus UV light source.

Related Reading