LISUN PFS power fail simulators to ISO 16750-2:2023 Clause 4.9: ±80V up to 300A, 1μs interruptions, <200ns switching, 16 signal line channels.
Enquire About This Product
Loose connectors, poor contacts and momentary shorts in a vehicle harness cause power and signal lines to drop out for microseconds or milliseconds. ISO 16750-2:2023 Clause 4.9 and carmaker specifications test whether electronic components ride through these interruptions.
The PFS series reproduces them with high-speed electronic switches and programmable timing, giving switching in under 200ns and interruptions from 1μs to 16s. One pair of power line channels handles up to ±80V and 50A to 300A, and 16 independent signal channels at ±50V/3A can be interrupted singly or together. It meets the requirements of Volkswagen, GM, BMW, Ford, Toyota and other carmakers, and is part of LISUN's LS-ISO16750 system.
| Specification | PFS-80V50A | PFS-80V100A | PFS-80V150A | PFS-80V300A |
|---|---|---|---|---|
| Power line interruption | ||||
| Max EUT supply | ±80V/50A | ±80V/100A | ±80V/150A | ±80V/300A |
| Functions | Power line interruption, short circuit, plug/unplug simulation | |||
| Switches | S1 (S+), S-, S2 | |||
| S2 discharge resistor | Open, 0Ω, 0.1Ω, 1Ω, 100Ω | |||
| Rise/fall time | <200ns | |||
| Voltage slew rate | >100V/μs, ≥20V/μs | |||
| Interruption time | 1μs~16s, with stepping | |||
| Calibration loads | 1Ω, 100Ω | |||
| Signal line interruption | ||||
| Max EUT supply | ±50V/3A | |||
| Channels | 16 independent, switchable | |||
| Test mode | Single or multiple channels at once | |||
| Rise/fall time | <200ns | |||
Choose a rating above the peak current your component draws. The PFS-80V50A suits most ECUs; higher-current models are for loads such as motors and heaters.
Yes. It has 16 independent signal channels rated ±50V/3A.