Programmable AC Power Source, 600VA to 5kVA
Straightforward AC-only test lines — home appliance testing, LED lighting qualification, and general manufacturing test stations — don't need the DC output mode or disturbance simulation capability of Preen's higher-tier AC sources; what they need is a compact, reliable programmable AC source covering the standard power and frequency range production testing actually requires. Preen's AFV-S series is built for exactly this segment, spanning 600VA to 5000VA with 0-310V output across a 40-500Hz frequency range.
Standard connectivity covers RS-232, RS-485, and PLC Remote interfaces, with Ethernet, Analog, and USB available as options — sufficient for most production-line integration without needing the AFV-P's more extensive standard interface set. The 5-inch touch screen displays 4 quick-access shortcuts drawn from 20 stored memory sets, a detail that matters more than it might first appear for a production line repeating the same handful of test profiles throughout a shift: operators can switch between stored configurations in seconds rather than re-entering parameters each time, and a screen lock function prevents accidental changes mid-run.
THD is held to ≤0.3% at 110V/220V, 50/60Hz — the standard mains conditions most home appliance and lighting test programmes actually test against — with response time under 300µs and over current foldback protection. The compact 2U (600-2500VA) or 4U (5000VA) form factor keeps rack space requirements modest for production floor installation.


| Output Phase | Single-phase (1Ø), 2 Wire + G |
| Output Power Range | 600VA–5000VA |
| Output Voltage Range | 0-155/0-310Vrms, user selectable |
| Output Frequency Range | 40-500Hz |
| Voltage Accuracy | ±(1% of setting + 0.1% F.S.) |
| Frequency Accuracy | ±0.02% |
| Total Harmonic Distortion (THD) | ≤0.3% at 110V/220V, 50Hz/60Hz · ≤0.5% (resistive load) |
| Line Regulation | ±0.1V |
| Load Regulation | ≤0.07% F.S. (resistive load) |
| Response Time | ≤300µs |
| Crest Factor | ≥3 |
| Inrush Current | ≤4× max. output current (RMS) |
| Efficiency | ≥77-80% at max. power (varies by model) |
| Program Mode / Memories | 20 Memories, 4 Shortcuts |
| Protections | OVP, LVP, OCP, OPP, OTP, RCP, Fan Fail & AMP Fail |
| Remote Interfaces | Standard: RS-232, RS-485, PLC Remote In&Out · Optional: Ethernet, Analog, USB |
| HMI | 5" touch screen with rotary knob |
| Operating Temperature | 0°C–40°C |
| Standout Feature — Over Current Foldback | Maintains constant output current while output voltage varies with load impedance, as an alternative to shutdown protection |
| Power | Voltage | Frequency | Max Current | ||
|---|---|---|---|---|---|
| AFV-S-600 | 600VA | 0-155/0-310Vrms | 40-500Hz | 10A | Enquire |
| AFV-S-1250 | 1250VA | 0-155/0-310Vrms | 40-500Hz | 20A | Enquire |
| AFV-S-2500 | 2500VA | 0-155/0-310Vrms | 40-500Hz | 20A | Enquire |
| AFV-S-5000 | 5000VA | 0-155/0-310Vrms | 40-500Hz | 40A | Enquire |