Home /
This is some text inside of a div block.
Programmable Power Supplies

Preen AFV-P Series

High-Performance Programmable AC Power Supply with DC Output, 600VA to 6kVA

A test bench that needs both AC grid simulation and DC bench testing traditionally needs two separate instruments — until the load calls for exactly the compact, dual-mode approach the AFV-P series was built around. Preen's AFV-P is a high-performance programmable AC power source that switches to a genuine DC output mode from the same unit, spanning 600VA to 6kVA, covering both functions from a single instrument rather than requiring a dedicated DC supply alongside a separate AC source.

Beyond the dual AC/DC capability, the AFV-P includes built-in Power Line Disturbance (PLD) simulation supporting IEC 61000-4-11, -14, and -28 pre-compliance testing — voltage dips, short interruptions, voltage variations, and frequency variation testing that would otherwise require separate dedicated PLD simulation equipment ahead of formal compliance testing on certified equipment. THD is held under 0.3% at 5-100Hz, with response time under 300µs, and active PFC raises input power factor to 0.98, reducing reactive current draw from the supply.

The current generation is meaningfully more compact than its predecessor — 50% lighter and roughly a third smaller — relevant where bench space or portable test setup constraints matter as much as electrical performance. Standard connectivity (RS-232, RS-485, Ethernet, USB) covers most automated test integration needs, with GPIB and Analog available as options for labs standardising on those interfaces specifically.

Preen AFV-P Series programmable AC power supply with DC output
Inquire About This Range →
AFV-P Series
Available as a Containerized / IP54 Option
Like Preen's BPS shore power series, the AFV-P Series can be built into a customized outdoor container or upgraded to an IP54-rated enclosure as an optional configuration — useful for ports, construction sites, remote installations, and other high humidity, heat, dust, or corrosion-exposed environments. Standard indoor chassis remain the default; contact Finch to configure a containerized or IP54 version for your application.
Preen AFV-P Series

AFV-P-800/1500/3000/6000 Family (350V)

High-performance programmable AC source with DC output, 350V range, 800VA-6000VA. A=5-2000Hz, B=15-1000Hz frequency variants.
Enquire About This Series →

Technical Specifications

Output PhaseSingle-phase (1Ø), 2 Wire + G
Output Power Range800VA–6000VA (also 600VA–5000VA line)
Output Voltage Range0-175/0-350Vrms or 0-155/0-310Vrms, user selectable
Output Frequency RangeType A: 5-2000Hz · Type B: 15-1000Hz
Voltage Accuracy±(0.5% of setting + 0.1% F.S.)
Frequency Accuracy±0.02%
Total Harmonic Distortion (THD)≤0.3% at 5-100Hz, rising to ≤2% at 1501-2000Hz (resistive load)
Line Regulation±0.1V
Load Regulation≤0.07% F.S. (resistive load)
Response Time≤300µs
Crest Factor≥3
Inrush Current≥4.5× max. output current (RMS), opt. 9× on select models
Efficiency≥77-85% at max. power (varies by model)
DC OutputYes — up to 5760W, 0-240V/0-480V selectable (800VA-6kVA line)
Input Power Factor≥0.98 (max. power) via active PFC circuit
Program Mode / Memories50 Memories & 1200 Steps (24 Steps/Memory), 4 Shortcuts (Basic Mode)
ProtectionsOVP, OCP, LVP, OPP, OTP, RCP, Fan Fail & AMP Fail (also VIN/PFC/DCB error, PWR OTP on 800VA-6kVA line)
Remote InterfacesStandard: RS-232, RS-485, Ethernet, USB, PLC Remote In&Out · Optional: GPIB, Analog
HMI5" touch screen with rotary knob
Operating Temperature0°C–40°C
Standout Feature — Power Line Disturbance SimulationUser-defined transient site (0-359°), voltage (0-350V) and dwell time (0.5-999.9ms) for IEC 61000-4-11/4-14/4-28 pre-compliance testing
Standout Feature — Start/End Angle SettingSelectable output start/end phase angle (0-359°), ideal for switching power supply inrush testing
ModelPowerAC VoltageFrequencyDC OutputWeight 
AFV-P-800A800VA0-175/0-350Vrms5-2000Hz768W12.9kgEnquire
AFV-P-800B800VA0-175/0-350Vrms15-1000Hz768W12.9kgEnquire
AFV-P-1500A1500VA0-175/0-350Vrms5-2000Hz1440W13.2kgEnquire
AFV-P-1500B1500VA0-175/0-350Vrms15-1000Hz1440W13.2kgEnquire
AFV-P-3000A3000VA0-175/0-350Vrms5-2000Hz2880W17.2kgEnquire
AFV-P-3000B3000VA0-175/0-350Vrms15-1000Hz2880W17.2kgEnquire
AFV-P-6000A6000VA0-175/0-350Vrms5-2000Hz5760W31.3kgEnquire
AFV-P-6000B6000VA0-175/0-350Vrms15-1000Hz5760W31.3kgEnquire
Preen AFV-P Series

AFV-P-600/1250/2500/5000 Family (310V)

High-performance programmable AC source with DC output, 310V range, 600VA-5000VA. A=5-2000Hz, B=15-1000Hz frequency variants. Optional 620V/1240V transformer boxes available for extended AC output range.
Enquire About This Series →
ModelPowerAC VoltageFrequencyDC OutputWeight 
AFV-P-600A600VA0-155/0-310Vrms5-2000Hz500W16kgEnquire
AFV-P-600B600VA0-155/0-310Vrms15-1000Hz500W16kgEnquire
AFV-P-1250A1250VA0-155/0-310Vrms5-2000Hz1000W20kgEnquire
AFV-P-1250B1250VA0-155/0-310Vrms15-1000Hz1000W20kgEnquire
AFV-P-2500A2500VA0-155/0-310Vrms5-2000Hz2000W31.3kgEnquire
AFV-P-2500B2500VA0-155/0-310Vrms15-1000Hz2000W31.3kgEnquire
AFV-P-5000A5000VA0-155/0-310Vrms5-2000Hz4000W61.5kgEnquire
AFV-P-5000B5000VA0-155/0-310Vrms15-1000Hz4000W61.5kgEnquire

Frequently Asked Questions

How does the AFV-P compare to the AFV-S series?
The AFV-P adds a genuine DC output mode and built-in PLD simulation to IEC 61000-4-11/-14/-28, which the AFV-S doesn't include, and extends to a wider optional frequency range. The AFV-S is AC-only, with a narrower standard frequency range, suited to straightforward AC-only test lines that don't need DC output or disturbance simulation. Finch has a dedicated comparison covering the two series in more depth for teams weighing this specific choice.
What does IEC 61000-4-11/-14/-28 pre-compliance testing actually cover?
IEC 61000-4-11 covers voltage dips, short interruptions, and voltage variations; IEC 61000-4-14 covers voltage fluctuations; IEC 61000-4-28 covers variation of power frequency. Together they represent common power line disturbance conditions equipment is required to tolerate under EMC compliance standards, and the AFV-P's built-in PLD function lets these be screened for ahead of formal certification testing.
Why would I need both AC and DC output from the same instrument?
Some test programmes need to evaluate a device under both AC grid-simulated conditions and DC bench power conditions — without dual-mode capability, this requires switching between two separate instruments, adding bench complexity and cost. The AFV-P's switchable AC/DC output covers both from one unit.